Generic methodology for the automated preparation and analysis of drug levels in plasma samples within a drug discovery environment was achieved through the redesign of a protein precipitation assay to a microtiter (96−well) plate format and the application of robotic liquid handling for performance of all transfer and pipetting steps. Validation studies revealed that the application of robotics to sample preparation, in general, maintained the analytical accuracy and precision compared with preparing samples manually. The use of rapid gradient LC-MS/MS for analysis coupled with flow diversion of the solvent front allowed the introduction of protein-precipitated samples into the mass spectrometer without the necessity for source cleaning. The problem inherent in automatically pipetting plasma, caused by fibrinogen clots, was overcome by storing samples at −80 °C and thus precluding clot formation. The resulting methodology allowed sample preparation for a 96-well plate designed to accommodate 54 unknowns, duplicate 12-point calibration curves, and 6 sets of quality controls at three levels in approximately 2 h. This approach allowed an increase in throughput of sample preparation and analysis to >400 samples per day per LC-MS/MS instrument with minimal manual intervention. Overall, substantial time savings were realized, demonstrating that automation is an increasingly essential tool in a drug discovery bioanalytical environment.Keywords
This publication has 18 references indexed in Scilit:
- Liquid−Liquid Extraction in the 96-Well Plate Format with SRM LC/MS Quantitative Determination of Methotrexate and Its Major Metabolite in Human PlasmaAnalytical Chemistry, 1999
- High-Throughput Bioanalytical LC/MS/MS Determination of Benzodiazepines in Human Urine: 1000 Samples per 12 HoursAnalytical Chemistry, 1999
- Peer Reviewed: Sample Preparation for LC/MS/MS: Analyzing Biological and Environmental SamplesAnalytical Chemistry, 1998
- Cassette dosing: rapid in vivo assessment of pharmacokineticsPharmaceutical Science & Technology Today, 1998
- New technologies for high-throughput screeningCurrent Opinion in Chemical Biology, 1997
- Applications of Combinatorial Technologies to Drug Discovery. 2. Combinatorial Organic Synthesis, Library Screening Strategies, and Future DirectionsJournal of Medicinal Chemistry, 1994
- Automatic solid-phase extraction and high-performance liquid chromatographic determination of quinidine in plasmaJournal of Chromatography A, 1994
- Applications of Combinatorial Technologies to Drug Discovery. 1. Background and Peptide Combinatorial LibrariesJournal of Medicinal Chemistry, 1994
- On-line solid-phase extraction with automated cartridge exchange for liquid chromatographic determination of lipophilic antioxidants in plasmaJournal of Chromatography A, 1994
- Characterization of Factors Affecting the Stability of Frozen Heparinized PlasmaVox Sanguinis, 1993