Surgical Management of the Patient with an Implanted Cardiac Device
- 1 November 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 230 (5) , 639-47
- https://doi.org/10.1097/00000658-199911000-00005
Abstract
To identify the sources of electromagnetic interference (EMI) that may alter the performance of implanted cardiac devices and develop strategies to minimize their effects on patient hemodynamic status. Since the development of the sensing demand pacemaker, EMI in the clinical setting has concerned physicians treating patients with such devices. Implanted cardiovertor defibrillators (ICDs) and ventricular assist devices (VADs) can also be affected by EMI. All known sources of interference to pacemakers, ICDs, and VADs were evaluated and preventative strategies were devised. All devices should be thoroughly evaluated before and after surgery to make sure that its function has not been permanently damaged or changed. If electrocautery is to be used, pacemakers should be placed in a triggered or asynchronous mode; ICDs should have arrhythmia detection suspended before surgery. If defibrillation is to be used, the current flow between the paddles should be kept as far away from and perpendicular to the lead system as possible. Both pacemakers and ICDs should be properly shielded if magnetic resonance imaging, positron emission tomography, or radiation therapy is to be used. The effect of EMI on VADs depends on the model. Magnetic resonance imaging adversely affects all VADs except the Abiomed VAD, and therefore its use should be avoided in this population of patients. The patient with an implanted cardiac device can safely undergo surgery as long as certain precautions are taken.Keywords
This publication has 12 references indexed in Scilit:
- The patient with a pacemaker or related deviceCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1996
- Laparoscopic cholecystectomy in 200 consecutive patients using an ultrasonically activated scalpel.1995
- Ultrasonic dissection.1994
- The NASPE */BPEG ** Defibrillator CodePacing and Clinical Electrophysiology, 1993
- Anaesthetic management of the patient with a permanent pacemakerAnaesthesia, 1989
- Current facts on pacemaker electromagnetic interference and their application to clinical care.1987
- Electrocautery and Pacemakers: Management of the Paced Patient Subject to ElectrocauteryThe Annals of Thoracic Surgery, 1986
- Effect of magnetic resonance imaging on DDD pacemakersThe American Journal of Cardiology, 1986
- The Effects of Nuclear Magnetic Resonance Imagers on External and Implantable Pulse GeneratorsPacing and Clinical Electrophysiology, 1984
- Artifacts and hazards in NMR imaging due to metal implants and cardiac pacemakers.1984