Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring System
- 1 April 2004
- journal article
- research article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 6 (2) , 105-113
- https://doi.org/10.1089/152091504773731285
Abstract
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System™ (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypoand hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 ± 1.1%, age 44.0 ± 11.4 years, and duration of diabetes 23.6 ± 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values ≤70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values ≥250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.Keywords
This publication has 14 references indexed in Scilit:
- Subcutaneous glucose sensor values closely parallel blood glucose during insulin‐induced hypoglycaemiaDiabetic Medicine, 2003
- The Effectiveness of Treatments of Diabetic Autonomic Neuropathy Is Not the Same in Autonomic Nerves Supplying Different OrgansDiabetes, 2003
- A Pilot Study of the Continuous Glucose Monitoring SystemDiabetes Care, 2001
- Limitations of Conventional Methods of Self-Monitoring of Blood GlucoseDiabetes Care, 2001
- Continuous Subcutaneous Glucose Monitoring in Children With Type 1 DiabetesPediatrics, 2001
- Clinical Utility of the Continuous Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2000
- Hypoglycemia and the Hypoglycemic Unawareness SyndromeDiabetes Technology & Therapeutics, 2000
- Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot studyDiabetes Research and Clinical Practice, 1999
- Is blood glucose predictable from previous values? A solicitation for data.Diabetes, 1999
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993