IOP measurement and central corneal thickness
Open Access
- 1 January 2002
- journal article
- mailbox
- Published by BMJ in British Journal of Ophthalmology
- Vol. 86 (1) , 120-121
- https://doi.org/10.1136/bjo.86.1.120
Abstract
In the recent paper by Feltgen and colleagues,1 the intraocular pressure (IOP) was measured by Goldmann applanation tonometry and by using a cannula inserted into the anterior chamber connected with a pressure transducer. Thus, the measurement took place omitting a possible influence of the cornea on the result. Marx et al 2 believed that by intracameral measurement the “true” intraocular pressure may be measured. Feltgen et al share his opinion. They believe, therefore, that they have compared the intraocular pressure measured with and without the possible influence of the cornea. Feltgen et al write in their conclusion: “There is no systematic error of applanation tonometry with increasing central corneal thickness (CCT). Therefore it is inadequate to recalculate IOP based on regression formula of applanatory IOP versus CCT.” They base their conclusion on their results. In our opinion their paper shows the following methodological deficits: (1) Both methods used for measuring IOP are not up to the demands of the scientific technique of measurement; (2) their intracamerally measured IOP values do not reflect the true IOP because of bias; (3) a non-significant regression coefficient does not prove that the slope is actually 0 and, therefore, by a non-significant regression coefficient it is not proved that applanatory readings are not influenced by CCT; (4) the goodness of fit of the linear regression model is insufficient; and (5) an important covariate (true IOP value) was omitted in the linear regression. We would like to discuss these points in detail. In the study of Feltgen et al the only criterion for the quality of measurement is the stability of the readings on the monitor. However, it is not sufficient to conclude from the presence of stability that the scale readings represent the “true” pressure value that is at the tip of the cannula. …Keywords
This publication has 8 references indexed in Scilit:
- Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readingsBritish Journal of Ophthalmology, 2001
- [More than 4 years' experience with electronic intraocular needle tonometry].Der Ophthalmologe, 1999
- Okulo-Oszillo-Dynamographie nach Ulrich und Ulrich: Ergebnisse bei AugengesundenKlinische Monatsblätter für Augenheilkunde, 1988
- [EEG tracings in cerebral death (author's transl)].1978
- Changes of the current pathways in the eye due to coating agents during electroretinographyAlbrecht von Graefes Archiv für Ophthalmologie, 1978
- Bandpass measurements in the electroretinographic electrode circuitAlbrecht von Graefes Archiv für Ophthalmologie, 1978
- Ein neues Verfahren zur Kalibrierung elektrophysiologischer UntersuchungseinheitenAlbrecht von Graefes Archiv für Ophthalmologie, 1977
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975