Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Open Access
- 1 December 2005
- journal article
- research article
- Published by American Diabetes Association in Diabetes Care
- Vol. 28 (12) , 2871-2876
- https://doi.org/10.2337/diacare.28.12.2871
Abstract
OBJECTIVE—We examined the reliability of two continuous glucose sensors in type 1 diabetic patients at night and during rapid glucose excursions and verified the hypothesized nocturnal hypoglycemic drift of the needle-type sensor (CGMSgold) and delay of the microdialysis sensor (GlucoDay). RESEARCH DESIGN AND METHODS—Blood was sampled overnight twice per hour in 13 patients. Rapid-acting insulin was given subcutaneously 30 min after breakfast. Sampling once per minute started 45 min after breakfast and 75 min after insulin injection for 30 min, with the aim of determining peak and nadir glucose values. Mean absolute differences (MADs) between sensor and blood glucose values were calculated. Sensor curves were modeled for all patients using linear regression. Horizontal and vertical shifts of sensor curves from the blood glucose curves were assessed. A vertical shift indicates sensor drift and a horizontal shift sensor delay. RESULTS—Drift was minimal in the needle-type and microdialysis sensors (−0.02 and −0.04 mmol/l). Mean ± SD delay was 7.1 ± 5.5 min for the microdialysis sensor (P < 0.001). MAD was 15.0% for the needle-type sensor and 13.6% for the microdialysis sensor (P = 0.013). After correction for the 7-min delay, the microdialysis MAD improved to 11.7% (P < 0.0001). CONCLUSIONS—The microdialysis sensor was more accurate than the needle-type sensor, with or without correction for a 7-min delay. In contrast to the previous version, the current needle-type sensor did not exhibit nocturnal hypoglycemic drift. Continuous subcutaneous glucose sensors are valuable adjunctive tools for glucose trend analyses. However, considering the large MADs, individual sensor values should be interpreted with caution.Keywords
This publication has 18 references indexed in Scilit:
- Defining and Reporting Hypoglycemia in DiabetesDiabetes Care, 2005
- Postprandial glucose monitoring in type 1 diabetes mellitus: use of a continuous subcutaneous monitoring deviceDiabetes/Metabolism Research and Reviews, 2004
- Evaluating the Accuracy of Continuous Glucose-Monitoring SensorsDiabetes Care, 2004
- Timing of Changes in Interstitial and Venous Blood Glucose Measured With a Continuous Subcutaneous Glucose SensorDiabetes, 2003
- Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin AnalogsDiabetes Care, 2003
- Reproducibility of the Continuous Glucose Monitoring System Matches Previous Reports and the Intended Use of the ProductDiabetes Care, 2003
- Spurious Reporting of Nocturnal Hypoglycemia by CGMS in Patients With Tightly Controlled Type 1 DiabetesDiabetes Care, 2002
- Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?Diabetes Care, 2002
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986