Physical Collection Efficiency of Filter Materials for Bacteria and Viruses
Open Access
- 14 October 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 51 (2) , 143-151
- https://doi.org/10.1093/annhyg/mel073
Abstract
The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10–900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button™ Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10–600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-μm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.Keywords
This publication has 19 references indexed in Scilit:
- Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks?American Journal of Infection Control, 2006
- Real-Time Fluorogenic Reverse Transcription-PCR Assays for Detection of Bacteriophage MS2Applied and Environmental Microbiology, 2006
- Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine ParticlesEnvironmental Health Perspectives, 2005
- Inactivation of Viruses in Bubbling Processes Utilized for Personal Bioaerosol MonitoringApplied and Environmental Microbiology, 2004
- Detection of Molecular Diversity in Bacillus atrophaeus by Amplified Fragment Length Polymorphism AnalysisApplied and Environmental Microbiology, 2004
- Bead-Based Electrochemical Immunoassay for Bacteriophage MS2Analytical Chemistry, 2004
- InfluenzaThe Lancet, 2003
- Reduction of Norwalk Virus, Poliovirus 1, and Bacteriophage MS2 by Ozone Disinfection of WaterApplied and Environmental Microbiology, 2003
- Inactivation of MS-2 phage and poliovirus in groundwaterCanadian Journal of Microbiology, 2000
- The Refined Structure of Bacteriophage MS2 at 2·8 Å ResolutionJournal of Molecular Biology, 1993