Protein adsorption and platelet adhesion onto polyurethane grafted with methoxy‐poly(ethylene glycol) methacrylate by plasma technique
- 1 December 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (12) , 1559-1567
- https://doi.org/10.1002/jbm.820271213
Abstract
Graft polymerization of methoxy-poly(ethylene glycol) methacrylate, an ester of methacrylic acid and monomethoxy-poly(ethylene glycol) (PEO), was performed onto a polyetherurethane (PU) film and tube under different polymerization conditions by a plasma treatment technique. The surface of grafted PU film was characterized by staining with dye, x-ray photoelectron spectroscopy, contact angle, and zeta potential. All these measurements indicated that water-soluble chains were immobilized on the PU surface, their location being restricted to the film surface region. The PU surface showed reduced protein adsorption in vitro and reduced platelet adhesion in vitro and ex vivo. The optimum graft density suppressing the protein adsorption was as low as 5 μg cm−2. When a small amount of dimethacrylate was added to the monomer solution for graft polymerization to introduce crosslinking in the grafted layer, protein adsorption was further slightly reduced. The extent of reduction in serum albumin adsorption was always less than that of γ-globulin. Although platelet adhesion was largely reduced by the surface graft polymerization, a definite amount of protein was always adsorbed to the grafted surface. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 19 references indexed in Scilit:
- Ozone‐induced graft polymerization onto polymer surfaceJournal of Polymer Science Part A: Polymer Chemistry, 1993
- Platelet deposition onto polymeric surfaces during shuntingJournal of Biomedical Materials Research, 1993
- Interactions of poly(ethylene glycol)-grafted cellulose membranes with proteins and plateletsBiomaterials, 1992
- Synthesis of photoreactive poly(ethylene glycol) and its application to the prevention of surface‐induced platelet activationJournal of Biomedical Materials Research, 1992
- Synthesis and characterization of SPUU–PEO–heparin graft copolymersJournal of Polymer Science Part A: Polymer Chemistry, 1991
- Blood compatibility of PEO grafted polyurethane and HEMA/styrene block copolymer surfacesJournal of Biomedical Materials Research, 1990
- Efficiency and Biocompatibility of a Polyethylene Glycol Grafted Cellulosic Membrane During HemodialysisAnnual Northeast Bioengineering Conference, 1989
- Oxidation of polyethylene surface by corona discharge and the subsequent graft polymerizationJournal of Polymer Science Part A: Polymer Chemistry, 1988
- Synthesis and Characterization of Non-Fouling Polymer Surfaces: I. Radiation Grafting of Hydroxyethyl Methacrylate and Polyethylene Glycol Methacrylate onto Silastic FilmJournal of Bioactive and Compatible Polymers, 1986
- Modification of polyetherurethane for biomedical application by radiation‐induced grafting. I. Grafting procedure, determination of mechanical properties, and chemical modification of grafted filmsJournal of Biomedical Materials Research, 1985