Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions
- 1 January 1997
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 40 (1) , 66-74
- https://doi.org/10.1002/(sici)1097-0304(199701)40:1<66::aid-ccd12>3.0.co;2-s
Abstract
We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX‐based quantitative coronary arteriography software program developed for rapid on‐line (digital) and off‐line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x‐ray system for on‐line analysis and has been designed to incorporate an integrated database, have on‐line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x‐ray vessel phantoms. Intra‐ and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x‐ray phantom studies (6‐in. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra‐ and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user‐independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications. Cathet Cardiovasc Diagn 40:66–74, 1997Keywords
This publication has 13 references indexed in Scilit:
- A Comparison of Hirudin with Heparin in the Prevention of Restenosis after Coronary AngioplastyNew England Journal of Medicine, 1995
- Comparative Validation of Quantitative Coronary Angiography SystemsCirculation, 1995
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Comparison of Directional Atherectomy with Coronary Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1993
- Prognostic significance of progression of coronary atherosclerosis.Circulation, 1993
- Accuracy and precision of quantitative digital coronary arteriography: Observer‐, short‐, and medium‐term variabilitiesCatheterization and Cardiovascular Diagnosis, 1993
- Does the new angiotensin converting enzyme inhibitor cilazapril prevent restenosis after percutaneous transluminal coronary angioplasty? Results of the MERCATOR study: a multicenter, randomized, double-blind placebo-controlled trial. Multicenter European Research Trial with Cilazapril after Angioplasty to Prevent Transluminal Coronary Obstruction and Restenosis (MERCATOR) Study Group.Circulation, 1992
- Calibration using angiographic catheters as scaling devices — Importance of filming the catheters not filled with contrast mediumThe American Journal of Cardiology, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986