Algorithms for optimal sequencing of dynamic multileaf collimators
- 15 December 2003
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (1) , 33-54
- https://doi.org/10.1088/0031-9155/49/1/003
Abstract
Dynamic multileaf collimator (DMLC) intensity modulated radiation therapy (IMRT) is used to deliver intensity modulated beams using a multileaf collimator (MLC), with the leaves in motion. DMLC-IMRT requires the conversion of a radiation intensity map into a leaf sequence file that controls the movement of the MLC while the beam is on. It is imperative that the intensity map delivered using the leaf sequence file be as close as possible to the intensity map generated by the dose optimization algorithm, while satisfying hardware constraints of the delivery system. Optimization of the leaf-sequencing algorithm has been the subject of several recent investigations. In this work, we present a systematic study of the optimization of leaf-sequencing algorithms for dynamic multileaf collimator beam delivery and provide rigorous mathematical proofs of optimized leaf sequence settings in terms of monitor unit (MU) efficiency under the most common leaf movement constraints that include leaf interdigitation constraint. Our analytical analysis shows that leaf sequencing based on unidirectional movement of the MLC leaves is as MU efficient as bi-directional movement of the MLC leaves.Keywords
This publication has 24 references indexed in Scilit:
- Minimizing delivery time and monitor units in static IMRT by leaf-sequencingPhysics in Medicine & Biology, 2002
- Intensity-modulated radiotherapy: current status and issues of interestInternational Journal of Radiation Oncology*Biology*Physics, 2001
- The MLC tongue-and-groove effect on IMRT dose distributionsPhysics in Medicine & Biology, 2001
- Generation of discrete beam-intensity modulation by dynamic multileaf collimation under minimum leaf separation constraintsPhysics in Medicine & Biology, 1998
- Beam characteristics of a retrofitted double‐focused multileaf collimatorMedical Physics, 1998
- Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profilesPhysics in Medicine & Biology, 1998
- Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Realization and verification of three-dimensional conformal radiotherapy with modulated fieldsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992