Stability of Arterial Concentrations during Continuous Inhalation of C15O2 and 15O2 and the Effects on Computed Values of CBF and CMRO2
Open Access
- 1 June 1988
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 8 (3) , 411-417
- https://doi.org/10.1038/jcbfm.1988.77
Abstract
Stability of arterial whole blood and plasma concentrations is a basic requirement in the application of the oxygen-15 (15O2) steady-state inhalation technique for measuring regional cerebral blood flow and oxygen use. The level of stability obtainable in practice is reported in the form of retrospectively analysed blood data from 626 consecutive studies in patients with a range of clinical conditions. Serial arterial whole blood and plasma concentrations were measured during both C15O2 and 15O2 inhalations, and coefficients of variation were calculated. In addition, these concentrations were compared with the corresponding values recorded at the start of each study and maximum variations were calculated. For all four concentrations, mean and median coefficients of variation were around 5 and 4%, respectively. Mean and median maximum variations were around 9 and 7%, respectively. The effects of these variations on the calculations of regional cerebral blood flow, oxygen extraction, and oxygen use were estimated. Mean expected errors were found to be between 4 and 9%, and median expected errors between 3 and 6%. Inherent blood sampling errors were assessed from blood volume studies using 11CO-labeled red cells. These errors were found to be <3%.Keywords
This publication has 20 references indexed in Scilit:
- Analysis of Some Errors in the Measurement of Oxygen Extraction and Oxygen Consumption by the Equilibrium Inhalation MethodJournal of Cerebral Blood Flow & Metabolism, 1985
- Measurement of Cerebral Blood Flow Using Bolus Inhalation of C15O2 and Positron Emission Tomography: Description of the Method and its Comparison with the C15O2 Continuous Inhalation MethodJournal of Cerebral Blood Flow & Metabolism, 1984
- Correction for the Presence of Intravascular Oxygen-15 in the Steady-State Technique for Measuring Regional Oxygen Extraction Ratio in the Brain: 2. Results in Normal Subjects and Brain Tumour and Stroke PatientsJournal of Cerebral Blood Flow & Metabolism, 1983
- Effect of Tissue Heterogeneity on the Measurement of Cerebral Blood Flow with the Equilibrium C15O2 Inhalation TechniqueJournal of Cerebral Blood Flow & Metabolism, 1983
- A Statistical Study of the Steady State Technique for Measuring Regional Cerebral Blood Flow and Oxygen Utilisation Using 15OJournal of Computer Assisted Tomography, 1982
- Error Analysis for the Determination of Cerebral Blood Flow with the Continuous Inhalation of 15O-Labeled Carbon Dioxide and Positron Emission TomographyJournal of Computer Assisted Tomography, 1982
- Editor's NoteJournal of Cerebral Blood Flow & Metabolism, 1981
- A New Journal and a New Society—Why?Journal of Cerebral Blood Flow & Metabolism, 1981
- A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopesPhysics in Medicine & Biology, 1979
- The continuous inhalation of Oxygen-15 for assessing regional oxygen extraction in the brain of manThe British Journal of Radiology, 1976