Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry
- 1 January 2000
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 5 (4) , 391-405
- https://doi.org/10.1117/1.1289359
Abstract
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to electronic fetal heart rate monitoring (cardiotocography) because it allows direct assessment of both the fetal oxygen status and fetal tissue perfusion. Here we present the analysis for determining the most optimal wavelength selection for pulse oximetry. The wavelengths we chose as the most optimal are the first in the range of 670-720 nm and the second in the range of 825-925 nm. Further, we discuss the possible systematic errors during our measurements and their contribution to the obtained saturation results. We present feasibility studies for fetal pulse oximetry, monitored noninvasively through the maternal abdomen. Our preliminary experiments show that the fetal pulse can be discriminated from the maternal pulse and thus, in principle, the fetal arterial oxygen saturation can be obtained. We present the methodology for obtaining these data, and discuss the dependence of our measurements on the fetal position with respect to the optode assembly.Keywords
This publication has 20 references indexed in Scilit:
- Feasibility of frequency domain NIR spectrometer to measure fetal cerebral blood oxygenation in uteroPublished by SPIE-Intl Soc Optical Eng ,1999
- The effect of uterine contractions on fetal oxygen saturationBJOG: An International Journal of Obstetrics and Gynaecology, 1995
- Diffusion-based model of pulse oximetry: in vitro and in vivo comparisonsApplied Optics, 1994
- The effect on fetal arteriolar oxygen saturation resulting from giving oxygen to the mother measured by pulse oximetryBJOG: An International Journal of Obstetrics and Gynaecology, 1993
- Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidaemia?BJOG: An International Journal of Obstetrics and Gynaecology, 1992
- Fetal monitoring with pulse oximetryBJOG: An International Journal of Obstetrics and Gynaecology, 1991
- Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetryIEEE Transactions on Biomedical Engineering, 1991
- Pulse oximetryJournal of Clinical Monitoring and Computing, 1989
- Pulse OximetryAnesthesiology, 1989
- Noninvasive pulse oximetry utilizing skin reflectance photoplethysmographyIEEE Transactions on Biomedical Engineering, 1988