Movement artefact rejection in impedance pneumography using six strategically placed electrodes
- 1 February 2000
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 21 (1) , 79-88
- https://doi.org/10.1088/0967-3334/21/1/310
Abstract
In this paper, we have proposed a technique for reducing movement artefacts in impedance pneumography by placing six electrodes at appropriate locations and suitably combining the measurements obtained. The strategy for electrode placement was based on the observation that the electrodes appeared to slide over the rib cage along with the skin, during movement. A volume conductor model of the thoracic cavity was developed and movement artefacts were simulated by shifting the electrodes to a different location on the surface. The impedance changes due to movement in one of the measurements of a 'symmetrical pair' were 180 degrees out of phase with respect to those observed in the other measurement of that pair. However, the impedance changes due to breathing were in phase in both these measurements. Thus, it was possible to reduce movement artefacts by taking a mean of these measurements without affecting the breathing related changes. The six electrodes could be configured into two such symmetrical pairs. The same observation was made in experimental data recorded from human subjects. This indicated that movement artefacts were caused by sliding of electrodes along with the skin and could be reduced by using the six-electrode configuration.Keywords
This publication has 8 references indexed in Scilit:
- Reduction of motion artefacts during paediatric/infant apnoea monitoringMedical & Biological Engineering & Computing, 1996
- Signal-to-motion artifact ratio versus frequency for impedance pneumographyIEEE Transactions on Biomedical Engineering, 1995
- Reduction of motion artifacts using a two-frequency impedance plethysmograph and adaptive filteringIEEE Transactions on Biomedical Engineering, 1995
- A real-time electrical impedance tomography system for clinical use-design and preliminary resultsIEEE Transactions on Biomedical Engineering, 1995
- A comparison of electrodes for potential use in paediatric/infant apnoea monitoringPhysiological Measurement, 1994
- The electrode system in impedance-based ventilation measurementIEEE Transactions on Biomedical Engineering, 1992
- Electrode Motion Artifacts in Electrical Impedance PneumographyIEEE Transactions on Biomedical Engineering, 1985
- Impedance pneumography—A survey of instrumentation techniquesMedical & Biological Engineering & Computing, 1966