Performance of the cobas CT/NG Test Compared to the Aptima AC2 and Viper CTQ/GCQ Assays for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
- 1 July 2012
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (7) , 2244-2249
- https://doi.org/10.1128/jcm.06481-11
Abstract
The next-generation amplification test for Chlamydia trachomatis and Neisseria gonorrhoeae (Roche cobas 4800), a fully automated system, was compared head to head, using female samples, to Gen-Probe Aptima Combo 2 and BD ProbeTec using Viper. Endocervical swabs, female urine, and endocervical samples in liquid-based cytology medium were run on at least two of three platforms. A total of 4,316 samples were evaluated, and 281 chlamydial and 69 gonococcal infections were identified. Estimates of sensitivity and specificity were obtained relative to the patient infection standard (PIS) and using latent class analysis (LCA). Chlamydia sensitivity estimates ranged from 86.9 to 95.6% using PIS and 97.6 to 98% using LCA. Specificity was ≥99.6% for all sample types. Sensitivity ranged from 95.6 to 100% using PIS and 96.9 to 100% using LCA for the detection of gonococcal infections. Specificity for gonococcal infections was ≥99.8%. cobas 4800 performance was equivalent to the comparator assays (all P values, >0.05), and the fully automated system provides high laboratory efficiency.This publication has 18 references indexed in Scilit:
- Evaluation of the Roche cobas® CT/NG Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Male UrineSexually Transmitted Diseases, 2012
- Performance of carcinogenic human papillomavirus (HPV) testing and HPV16 or HPV18 genotyping for cervical cancer screening of women aged 25 years and older: a subanalysis of the ATHENA studyThe Lancet Oncology, 2011
- Clinical Evaluation of the BD ProbeTec™ Chlamydia trachomatis Qx Amplified DNA Assay on the BD Viper™ System With XTR™ TechnologySexually Transmitted Diseases, 2011
- Evaluation of the Abbott RealTi m e CT/NG Assay in Comparison to the Roche Cobas Amplicor CT/NG AssayJournal of Clinical Microbiology, 2011
- First Report of Performance of the Versant CT/GC DNA 1.0 Assay (kPCR) for Detection of Chlamydia trachomatis and Neisseria gonorrhoeaeJournal of Clinical Microbiology, 2011
- Validation of the APTIMA Combo 2 Assay for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in SurePath Liquid-Based Pap Test Samples Taken With Different Collection DevicesSexually Transmitted Diseases, 2009
- Utility of Composite Reference Standards and Latent Class Analysis in Evaluating the Clinical Accuracy of Diagnostic Tests for PertussisClinical and Vaccine Immunology, 2008
- Evaluation of Gen-Probe APTIMA-Based Neisseria gonorrhoeae and Chlamydia trachomatis Confirmatory Testing in a Metropolitan Setting of High Disease PrevalenceJournal of Clinical Microbiology, 2007
- Multicenter Evaluation of the BDProbeTec ET System for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Urine Specimens, Female Endocervical Swabs, and Male Urethral SwabsJournal of Clinical Microbiology, 2001
- Detection of Chlamydia trachomatis in Genitourinary Tract Specimens Using an Automated Enzyme-Linked Fluorescent ImmunoassaySexually Transmitted Diseases, 1996