Precision and Accuracy of Dual‐Energy X‐ray Absorptiometry for Determining in Vivo Body Composition of Mice
- 1 August 2000
- journal article
- Published by Wiley in Obesity Research
- Vol. 8 (5) , 392-398
- https://doi.org/10.1038/oby.2000.47
Abstract
Objective: To evaluate the precision and accuracy of dual‐energy X‐ray absorptiometry (DXA) for the measurement of total‐bone mineral density (TBMD), total‐body bone mineral (TBBM), fat mass (FM), and bone‐free lean tissue mass (LTM) in mice.Research Methods and Procedures: Twenty‐five male C57BL/6J mice (6 to 11 weeks old; 19 to 29 g) were anesthetized and scanned three times (with repositioning between scans) using a peripheral densitometer (Lunar PIXImus). Gravimetric and chemical extraction techniques (Soxhlet) were used as the criterion method for the determination of body composition; ash content was determined by burning at 600°C for 8 hours.Results: The mean intraindividual coefficients of variation (CV) for the repeated DXA analyses were: TBMD, 0.84%; TBBM, 1.60%; FM, 2.20%; and LTM, 0.86%. Accuracy was determined by comparing the DXA‐derived data from the first scan with the chemical carcass analysis data. DXA accurately measured bone ash content (p = 0.942), underestimated LTM (0.59 ± 0.05g, p < 0.001), and overestimated FM (2.19 ± 0.06g, p < 0.001). Thus, DXA estimated 100% of bone ash content, 97% of carcass LTM, and 209% of carcass FM. DXA‐derived values were then used to predict chemical values of FM and LTM. Chemically extracted FM was best predicted by DXA FM and DXA LTM [FM = −0.50 + 1.09(DXA FM) − 0.11(DXA LTM), model r2 = 0.86, root mean square error (RMSE) = 0.233 g] and chemically determined LTM by DXA LTM [LTM = −0.14 + 1.04(DXA LTM), r2 = 0.99, RMSE = 0.238 g].Discussion: These data show that the precision of DXA for measuring TBMD, TBBM, FM, and LTM in mice ranges from a low of 0.84% to a high of 2.20% (CV). DXA accurately measured bone ash content but overestimated carcass FM and underestimated LTM. However, because of the close relationship between DXA‐derived data and chemical carcass analysis for FM and LTM, prediction equations can be derived to more accurately predict body composition.Keywords
This publication has 12 references indexed in Scilit:
- Increased cortical bone mineral content but unchanged trabecular bone mineral density in female ERβ–/– miceJournal of Clinical Investigation, 1999
- Quantitative Trait Loci Affecting Peak Bone Mineral Density in MiceJournal of Bone and Mineral Research, 1998
- Evaluation of Dual-Energy X-Ray Absorptiometry for Body-Composition Assessment in RatsJournal of Nutrition, 1998
- Total body lipid and triglyceride response to energy deficit: relevance to body composition modelsAmerican Journal of Physiology-Endocrinology and Metabolism, 1998
- Whole Body Composition of Rats Determined by Dual Energy X-Ray Absorptiometry Is Correlated with Chemical AnalysisJournal of Nutrition, 1998
- Precision and accuracy of total body bone mass and body composition measurements in the rat using x-ray-based dual photon absorptiometryCanadian Journal of Physiology and Pharmacology, 1997
- Improvement in the Accuracy of Dual Energy X-ray Absorptiometry for Whole Body and Regional Analysis of Body Composition: Validation Using Piglets and Methodologic Considerations in InfantsPediatric Research, 1997
- Dual-energy X-ray absorptiometry for the measurement of gross body composition in ratsBritish Journal of Nutrition, 1996
- The Use of Dual-Energy X-ray Absorptiometry in AnimalsInvestigative Radiology, 1996
- The effect of apparatus, extraction time, and solvent type on lipid extractions of snow geeseCanadian Journal of Zoology, 1985