Abstract
Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.Keywords
This publication has 20 references indexed in Scilit:
- A Direct Comparison of Noninvasive Coronary Angiography by Electron Beam Tomography and Navigator-Echo-Based Magnetic Resonance Imaging for the Detection of Restenosis Following Coronary AngioplastyInvestigative Radiology, 2002
- Three‐dimensional true‐FISP imaging of the coronary arteries: Improved contrast with T2‐preparationJournal of Magnetic Resonance Imaging, 2002
- Magnetic Resonance–Guided Coronary Artery Stent Placement in a Swine ModelCirculation, 2002
- Coronary Magnetic Resonance Angiography for the Detection of Coronary StenosesNew England Journal of Medicine, 2001
- Direct comparison of 3D spiral vs. Cartesian gradient‐echo coronary magnetic resonance angiographyMagnetic Resonance in Medicine, 2001
- Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR AngiographyRadiology, 1999
- Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiographyJournal of the American College of Cardiology, 1999
- Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRACirculation, 1999
- Invited. Remember true FISP? a high SNR, near 1‐second imaging method for T2‐like contrast in interventional MRI at .2 TJournal of Magnetic Resonance Imaging, 1998
- Fast Spiral Coronary Artery ImagingMagnetic Resonance in Medicine, 1992