Automated haematology analysis to diagnose malaria
Open Access
- 30 November 2010
- journal article
- review article
- Published by Springer Nature in Malaria Journal
- Vol. 9 (1) , 346
- https://doi.org/10.1186/1475-2875-9-346
Abstract
For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn®, Coulter® GEN·S and LH 750, and the Sysmex XE-2100® analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the method is applied. Future developments in new haematology analysers such as considerably simplified, robust and inexpensive devices for malaria detection fitted with an automatically generated alert could improve the detection capacity of these instruments and potentially expand their clinical utility in malaria diagnosis.Keywords
This publication has 58 references indexed in Scilit:
- Automated Detection of Malaria-Associated Pseudoeosinophilia and Abnormal WBC Scattergram by the Sysmex XE-2100 Hematology Analyzer: A Clinical Study with 1,801 Patients and Real-Time Quantitative PCR Analysis in Vivax Malaria-Endemic AreaThe American Journal of Tropical Medicine and Hygiene, 2010
- Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology AnalyzerThe American Journal of Tropical Medicine and Hygiene, 2010
- Is flow cytometry better in counting malaria pigment-containing leukocytes compared to microscopy?Malaria Journal, 2009
- Diagnosis of acute malaria by laser based cell counter with comparison of conventional and recent techniques in Indian scenarioIndian Journal of Pathology and Microbiology, 2009
- Evaluation of Usefulness of the Panel Test Composed of Malaria Non-specific Tests As a Surrogate MarkerAnnals of Laboratory Medicine, 2008
- Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severityMalaria Journal, 2008
- Three Cases of Pseudoeosinophilia Associated with Malaria Determined in the Sysmex XE-2100 Automated Hematology AnalyzerAnnals of Laboratory Medicine, 2006
- Automated detection of malaria by means of the haematology analyser CoulterR GEN.STMClinical and Laboratory Haematology, 2004
- Flow cytometric screening of blood samples for malaria parasitesCytometry, 1993