Impact of Humidification Systems on Ventilator-associated Pneumonia
- 15 November 2005
- journal article
- research article
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 172 (10) , 1276-1282
- https://doi.org/10.1164/rccm.200408-1028oc
Abstract
The respective influence on the incidence of ventilator-associated pneumonia of currently available systems used for warming and humidifying the gases delivered to mechanically ventilated patients, that is, heated humidifiers and heat and moisture exchanger filters, remains controversial. We addressed this question in a multicenter randomized study comparing heated humidifiers (with heated circuits) and filters in an unselected population of 369 intensive care patients receiving mechanical ventilation for more than 48 h. The diagnosis of pneumonia was confirmed according to strict microbiologic criteria. There was no difference in pneumonia rate between the two groups (53 of 184 [28.8%] versus 47 of 185 [25.4%] for humidifiers versus filters; p = 0.48), or in the incidence density of pneumonia (27.4/1,000 ventilatory days versus 25.3/1,000 ventilatory days for humidifiers versus filters; p = 0.76). The mean duration of mechanical ventilation did not differ between the two groups (14.9 +/- 15.1 versus 13.5 +/- 16.3 days for humidifiers versus filters, p = 0.36). Endotracheal tube occlusion occurred, respectively, in five patients and one patient in the humidifier and filter groups (p = 0.12). Intensive care mortality was identical in the two groups (about 33%). These results suggest that both heated humidifiers and heat and moisture exchanger filters can be used with no significant impact on the incidence of ventilator-associated pneumonia and that other criteria may justify their choice.Keywords
This publication has 32 references indexed in Scilit:
- Long-term Effects of Different Humidification Systems on Endotracheal Tube PatencyAnesthesiology, 2004
- Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: A prospective clinical, hygrometric, and bacteriologic studyCritical Care Medicine, 2003
- Heat and moisture exchangers in mechanically ventilated intensive care unit patients: A plea for an independent assessment of their performanceCritical Care Medicine, 2003
- A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumoniaAmerican Journal of Infection Control, 2001
- The Prevention of Ventilator-Associated PneumoniaNew England Journal of Medicine, 1999
- How to use an article on therapy or preventionCritical Care Medicine, 1997
- Prospective, Randomized Study of Ventilator-Associated Pneumonia in Patients With One Versus Three Ventilator Circuit Changes Per WeekInfection Control & Hospital Epidemiology, 1996
- A New Simplified Acute Physiology Score (SAPS II) Based on a European/North American Multicenter StudyJAMA, 1993
- Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilationIntensive Care Medicine, 1992
- Heat and Moisture Exchangers and Vaporizing Humidifiers in the Intensive Care UnitChest, 1990