Poly(ethyleneimine) modified filters for the removal of leukocytes from blood
- 1 October 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (10) , 1253-1268
- https://doi.org/10.1002/jbm.820271006
Abstract
Polyurethane membrane filters and filters coated with poly(ethyleneimine) were used to investigate the influence of leukocyte adhesion during filtration. Treatment of the filters with an aqueous solution of 1% (w/v) poly(ethyleneimine) (PEI) led to the introduction of amine groups at the filter surfaces, as was confirmed by X-ray photoelectron spectroscopy. The modification procedure did not significantly change the porous structure in the filters, as was demonstrated by SEM and porometry. Using 14C-labeled poly(ethyleneimine) it was shown that nearly a complete coverage (∼0.1 mg/m2) was achieved that did not desorb from the filter surface during contact with blood plasma. When the filtration was carried out with purified leukocytes in the absence of red cells, platelets, and blood plasma, the number of cells removed by modified filters (>95%) was significantly higher as compared to the removal with unmodified filters (∼80%). However, no significant differences between the filters were found when the filtration was performed with whole blood. This finding was unexpected, because it was shown before that immobilization of poly(ethyleimine) on solid polyurethane film, surfaces promoted the adhesion of leukocytes from whole blood. Apparently, the adhesive properties of the PEI diminish during filtration. Filter coating of commercial leukocyte filters composed of polyester fibers also had no effect on the removal of leukocytes from whole blood. It was postulated that morphological factors, such as filter shape, roughness, tortuosity, and porosity rather than the physicochemical properties of the filter surface influence cell adhesion to the filter surface, and through that the filtration process. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 49 references indexed in Scilit:
- Modification of transport properties of ion exchange membrane. XI. Electrodialytic properties of cation exchange membranes having polyethyleneimine layer fixed by acid–amide bondingJournal of Applied Polymer Science, 1990
- An Objective Characterization of the Cell Size of Microcellular FoamsJournal of Cellular Plastics, 1988
- Physical and hydrodynamic factors affecting erythrocyte adhesion to polymer surfacesJournal of Biomedical Materials Research, 1988
- Activation of Complement by Blood Transfusion Filter1Vox Sanguinis, 1983
- Effectiveness of Red Blood Cells Filtered Through Cotton Wool to Prevent Antileukocyte Antibody Production in Multitransfused PatientsVox Sanguinis, 1982
- Catalysis by polymer complexes. VIII. Enhanced nucleophilic reactivity of hydroxamate anions bound to quaternized polyethylenimines and related compoundsJournal of Polymer Science: Polymer Chemistry Edition, 1978
- Blood Filter EvaluationBiomaterials, Medical Devices, and Artificial Organs, 1977
- Removal of Buffy Coat from Stored ACD Blood by Dextran: Agglomeration and Subsequent FiltrationVox Sanguinis, 1973
- Physical Entrapment of Polyelectrolytes within Microporous Solids: the “Jack-in-the-Box” EffectNature, 1970
- Separation of Lymphocytes from Human BloodActa Haematologica, 1966