Radiological quality of coronary guiding catheters: A quantitative analysis
- 1 September 1994
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 33 (1) , 55-60
- https://doi.org/10.1002/ccd.1810330115
Abstract
Quantitative coronary angiography (QCA) is a validated and widely accepted method to investigate changes in arterial dimension over time. Calibration of measurements is enabled by the use of the coronary catheter as a scaling device. The dimensions and laminar composition of coronary catheters, however, have changed significantly over recent years and the suitability of the current generation of coronary catheters for calibration purposes has not been validated. We therefore recorded 57 coronary guiding catheters on cinefilm, and compared their automated quantitative measurements (Cardiovascular Angiography Analysis System, CAAS) with their true values (precision micrometer). We found an overall underestimation of quantitatively derived dimensions, ranging from −8.9 to +4% for water‐filled catheters and from −15.5 to −3.9% for contrast‐filled catheters. In conclusion, while the current generation of coronary guiding catheters shows a wide variety in radiological quality, it can be clearly detected by the CAAS system, and is suitable for calibration of QCA measurements (with the exception of the DVI atherectomy catheter), provided that calibration is done on contrast‐empty catheters. © Wiley‐Liss, Inc.Keywords
This publication has 15 references indexed in Scilit:
- Experimental validation of geometric and densitometric coronary measurements on the new generation cardiovascular angiography analysis system (caas ii)Catheterization and Cardiovascular Diagnosis, 1993
- Discordant results of visual and quantitative estimates of stenosis severity before and after coronary angioplastyCatheterization and Cardiovascular Diagnosis, 1993
- Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch® coronary contrast catheters from digital and cine arteriogramsThe International Journal of Cardiovascular Imaging, 1992
- Effect of digoxin on contractility and symptoms in infants with a large ventricular septal defectThe American Journal of Cardiology, 1991
- Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiographyThe American Journal of Cardiology, 1991
- Accuracy and reproducibility of quantitative coronary arteriography using 6 and 8 french catheters with cine angiographic acquisitionCatheterization and Cardiovascular Diagnosis, 1991
- Evaluation of catheters and metallic catheter markers as calibration standard for measurement of coronary dimensionCatheterization and Cardiovascular Diagnosis, 1990
- Accuracy of individual and panel visual interpretations of coronary arteriograms; Implications for clinical decisionsJournal of the American College of Cardiology, 1990
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Assessment of dimensions and image quality of coronary contrast catheters from cineangiogramsCatheterization and Cardiovascular Diagnosis, 1985