An Implantable Strain Measurement System Designed to Detect Spine Fusion
- 1 March 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Spine
- Vol. 27 (5) , 487-497
- https://doi.org/10.1097/00007632-200203010-00009
Abstract
The strain distribution on the thoracic vertebrae during anteroposterior bending and torsion was examined for use with an implantable strain gauge system and miniature radio transmitter, which also were evaluated. To identify strain gauge placement sites by testing cadaver spines in vivo, and to evaluate an implantable gauge bonding technique and subminiature radio transmitter for accurate strain monitoring. Fusion is determined currently through the use of radiographic techniques. Discrepancies exist between radiographic evidence and more direct measurements of fusion such as operative exploration4,5,12 and biomechanical or histologic measurements.12,15 To facilitate the return of patients to full unrestricted activity, it would be useful to develop a technique for accurate in vivo determination of fusion. Three cadaver spines were tested during anteroposterior bending and torsional loading in the control, instrumented, and instrumented plus polymethylmethacrylate states. The spines were instrumented with an ISOLA(R) (Acromed Corporation, Cleveland, Ohio) construct, and a simulated fusion was achieved through the application of polymethylmethacrylate. Strain gauges were attached in uniaxial, biaxial, and rosette configurations. The principal strains were calculated. Calcium phosphate ceramic-coated gauges were implanted in patients and recovered after up to 15 months in vivo. A radio transmitter was developed and tested for use in patients. The largest and most consistent strain changes after simulated fusion were recorded during torsional loading on the laminae of a vertebra directly underneath a hook. Calcium phosphate ceramic-coated strain gauges showed excellent bone bonding to the lamina when fusion occurred. Radio telemetry accurately tracked strain magnitudes and strain rates expected in patients. The consistency obtained in torsional loading indicates that this type of loading will provide the most useful data from patients in vivo. Excellent bonebonding and accurate strain transmission using a long-term strain measurement system and miniature radio transmitter indicate that strains collected from patients with this system will be accurate.Keywords
This publication has 27 references indexed in Scilit:
- Abstracts of the 15th Annual Meeting of the Academy of Surgical Research, Scottsdale, Arizona, September 2-4, 1999: POSTER PRESENTATIONSJournal of Investigative Surgery, 1999
- Load transfer through a hydroxyapatite‐coated canine hip implantJournal of Applied Biomaterials, 1994
- Strain Redistribution in the Canine Femur Resulting from Hip Implants of Different StiffnessesJournal of Investigative Surgery, 1994
- In Vivo Strain Analysis of the Greyhound Femoral DiaphysisJournal of Investigative Surgery, 1992
- Technical note. Comparison of the deformation response of synthetic and cadaveric femora during simulated one‐legged stanceJournal of Applied Biomaterials, 1991
- Operative Treatment of Spinal Fractures with the AO Internal FixatorSpine, 1991
- Preliminary development of a hydroxyapatite‐backed strain gaugeJournal of Applied Biomaterials, 1990
- 1989 Volvo Award in Basic Science: Device-Related Osteoporosis with Spinal InstrumentationSpine, 1989
- Spinal Bone Density Following Spinal FusionSpine, 1989
- Internal Fixation in Lumbosacral Spine Fusion A Biomechanical and Clinical StudyPublished by Wolters Kluwer Health ,1986