Microvascular blood flow and skin temperature changes in the fingers following a deep inspiratory gasp
- 14 March 2002
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 23 (2) , 365-373
- https://doi.org/10.1088/0967-3334/23/2/312
Abstract
The aims of this study were to quantify the changes in finger pulp skin temperature, laser Doppler flow (LDF, microvascular flux) and photoplethysmogram (PPG, microvascular blood volume pulsatility), induced by a deep inspiration in healthy subjects, and to investigate the repeatability of these responses within a measurement session and between measurement sessions on separate days. A system comprising an electronic thermometer, a laser Doppler flowmeter and a PPG amplifier measured simultaneous vasoconstrictor responses to a deep inspiratory gasp from three adjacent fingers of one hand. Clearly defined responses were obtained in 15 of the 17 subjects studied. Skin temperature fell in all of these subjects after each gasp, with a median fall of 0.089 °C (P < 0.001). The median value of LDF flux reduction was 93% (P < 0.001) indicating a momentary almost complete shut-down of microvascular blood flow; and PPG also showed a large response relative to pulse amplitude of 2.6 (P < 0.001). The median times for waveforms to reach their minimum were 4.6 s (PPG), 6.3 s (LDF) and 29.1 s (skin pulp temperature), with median delays between minima of LDF and PPG of 1.6 s (P < 0.001) and skin temperature and PPG of 23.5 s (P < 0.001). The vascular responses of skin temperature, LDF and PPG to an inspiratory gasp were repeatable, with temperature change repeatable to within 10% of the median subject change.Keywords
This publication has 11 references indexed in Scilit:
- Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling.Medical & Biological Engineering & Computing, 2001
- Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toesIEE Proceedings - Science, Measurement and Technology, 2000
- Transient phase locking patterns among respiration, heart rate and blood pressure during cardiorespiratory synchronisation in humansMedical & Biological Engineering & Computing, 2000
- Fingertip temperature as an indicator for sympathetic responsesPublished by Elsevier ,1998
- Sympathetic vasoconstrictor reflex pattern in patients with complex regional pain syndromePain, 1998
- Spontaneous Flow Waves Detected by Laser Doppler in Human SkinMicrovascular Research, 1995
- DC photoplethysmography in the evaluation of sympathetic vasomotor responsesClinical Physiology and Functional Imaging, 1993
- Repeatability of measurements and sources of variability in tests of cardiovascular autonomic functionHeart, 1992
- Observations on the photoplethysmograph pulse derived from a laser Doppler flowmeterClinical Physics and Physiological Measurement, 1989
- Noninvasive Measurement of the Human Peripheral Circulation: Relationship Between Laser Doppler Flowmeter and Photoplethysmograph Signals from the FingerAngiology, 1988