Determination of Plasma Glucose During Rapid Glucose Excursions with a Subcutaneous Glucose Sensor
- 1 February 2003
- journal article
- research article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 5 (1) , 27-31
- https://doi.org/10.1089/152091503763816436
Abstract
Continuous glucose monitoring has the potential to improve glucose management and reduce the risk of hypoglycemia in individuals with diabetes. Accurate sensors may also allow the development of a closed-loop insulin delivery system. The purpose of this work was to determine the delay time associated with a subcutaneous glucose sensor during rapidly changing glucose excursions. Subcutaneous glucose sensors (Medtronic MiniMed, Inc., Northridge, CA) were inserted in five healthy men. After a 2-h stabilization period, a 3-h hyperglycemic (~11 mM) clamp was performed followed by a 90-min period in which plasma glucose was allowed to decline to as low as 2.8 mM. Sensors were calibrated using two points (basal and hyperglycemia), and the calibrated sensor glucose measurements were compared with those from a reference analyzer (Beckman Instruments, Fullerton, CA). Response time was estimated from a first-order kinetic model. Plasma glucose levels, determined with the subcutaneous sensor, were highly correlated with those obtained with the reference glucose analyzer (r2 = 0.91, p < 0.001; mean absolute difference of ~8%). The half-time for the sensor response was estimated to be 4.0 ± 1.0 min. The subcutaneous glucose sensor has the potential to facilitate the detection of hypoglycemia and improve overall glycemic control when used in a real-time monitor. The rapid response should be sufficient to allow a fully automated closed-loop insulin delivery system to be developed based on the subcutaneous sensing site.Keywords
This publication has 9 references indexed in Scilit:
- Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?Diabetes Care, 2002
- Physiological Influences on Off-Finger Glucose TestingDiabetes Technology & Therapeutics, 2001
- Accuracy of Glucose Meter Use in Gestational DiabetesDiabetes Technology & Therapeutics, 2001
- The MiniMed Continuous Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2000
- Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home UseDiabetes Technology & Therapeutics, 2000
- Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoringAmerican Journal of Physiology-Endocrinology and Metabolism, 1999
- Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulinProceedings of the National Academy of Sciences, 1998
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- On Line Continuous Monitoring of Subcutaneous Tissue Glucose is Feasible by Combining Portable Glucosensor with MicrodialysisHormone and Metabolic Research, 1993