Effects of Insertion Depth of Cochlear Implant Electrodes upon Speech Perception
- 15 April 2004
- journal article
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 9 (3) , 163-172
- https://doi.org/10.1159/000077267
Abstract
Objective: To investigate whether the insertion depth of a cochlear implant array affects postoperative speech perception. Design: The subjects were 48 postlingually deaf adults who received either the Nucleus 22 or the Nucleus 24 cochlear implant with a straight array. A postoperative radiograph of the cochlear electrode was used to estimate insertion depth, as either the angle of the electrode tip (angle) or the intracochlear length of the electrode (length). Other estimates of insertion depth included the numbers of active electrodes and channels used by the speech processor. Electrode depth, together with the duration of deafness, hearing aid usage, pre-operative speech perception score and pre-operative pure-tone averages were independent variables in a forward stepwise multiple regression analysis, where the dependent variables were postoperative CNC words and CNC phonemes. Results: Duration of deafness and insertion depth (angle, insertion length or active electrodes) were the predictive variables for CNC words or CNC phonemes. Angle was the best ‘depth-related’ predictor of postoperative speech perception. An even clearer relationship was found between CUNY sentences in noise and angle, in a subset of 26 patients. Conclusion: Depth of electrode insertion affects postoperative speech perception.Keywords
This publication has 10 references indexed in Scilit:
- Spatial spread of neural excitation in cochlear implant recipients: comparison of improved ECAP method and psychophysical forward maskingHearing Research, 2003
- Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depthThe Journal of the Acoustical Society of America, 2003
- Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implantThe Journal of the Acoustical Society of America, 2002
- CT-Derived Estimation of Cochlear Morphology and Electrode Array Position in Relation to Word Recognition in Nucleus-22 RecipientsJournal of the Association for Research in Otolaryngology, 2002
- Adaptation by normal listeners to upward spectral shifts of speech: Implications for cochlear implantsThe Journal of the Acoustical Society of America, 1999
- The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear-implant signal processors with 6–20 channelsThe Journal of the Acoustical Society of America, 1998
- Speech recognition with altered spectral distribution of envelope cuesThe Journal of the Acoustical Society of America, 1998
- Effects of Formant Bandwidth on the Identification of Synthetic Vowels by Cochlear Implant RecipientsEar & Hearing, 1997
- Simulating the effect of cochlear-implant electrode insertion depth on speech understandingThe Journal of the Acoustical Society of America, 1997
- Single fiber mapping of spatial excitation patterns in the electrically stimulated auditory nerveHearing Research, 1987