2D and 3D high frame rate imaging with limited diffraction beams
- 1 July 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 44 (4) , 839-856
- https://doi.org/10.1109/58.655200
Abstract
A new 2D (two-dimensional) and 3D (three-dimensional) pulse-echo imaging method (Fourier method) has been developed with limited diffraction beams. In this method, a plane wave pulse (broadband) is used to transmit and limited diffraction beams of different parameters are used to receive. Signals received are processed to obtain spatial Fourier transform of object functions and images are constructed with an inverse Fourier transform. Because only one transmission is required to construct images, this method may achieve a high frame rate (up to 3750 frames/s for biological soft tissues at a depth of 200 mm). To demonstrate the efficacy of the method, both 2D C-mode and 3D images have been simulated using conditions that are typical for medical ultrasound. Results show that images of high resolutions (about 6 wavelengths at 200 mm) and low sidelobes (around -60 dB) can be constructed over a large depth of interest (30 to 200 mm) with a 50 mm diameter aperture. Experiments with the new method have also been carried out. 2D B-mode images have been constructed with conventional linear arrays. In the experiment, an ATS 539 tissue-equivalent phantom and two linear arrays were used. The first array had a center frequency of 2.25 MHz, dimension of 18.288 mm/spl times//spl times/12.192 mm, and 48 elements. The second had a center frequency of 2.5 MHz, 38.4 mm/spl times/10 mm in dimension, and 64 elements. Images of different fields of views were constructed from RF data acquired with these arrays using both the new and conventional dynamic focusing (delay-and-sum) methods. Results show that qualities of images constructed are almost identical with the two methods in terms of sidelobes, contrast, and lateral and axial resolutions. Phase aberration has also been assessed for the two methods, and results show that its influence is about the same on both methods. In addition, a practical imaging system to implement the new method is suggested and potential applications of the method are discussed.Keywords
This publication has 61 references indexed in Scilit:
- Estimation of piezoelectric material properties by coupling theory and FEMPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Designing limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- A new approach to obtain limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- A study of two-dimensional array transducers for limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1994
- Ultrasound synthetic aperture imaging: monostatic approachIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1994
- Graphical simulation of superluminal acoustic localized wave pulsesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1994
- Evidence of Localized Wave TransmissionPhysical Review Letters, 1989
- Spectral analysis of focus wave modesJournal of the Optical Society of America A, 1987
- Exact solutions of the wave equation with complex source locationsJournal of Mathematical Physics, 1985
- Focus waves modes in homogeneous Maxwell’s equations: Transverse electric modeJournal of Applied Physics, 1983