3.0 Tesla Magnetic Resonance Angiography of Endovascular Aortic Stent Grafts
- 1 July 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 39 (7) , 413-417
- https://doi.org/10.1097/01.rli.0000129470.63758.c1
Abstract
This study evaluated different stent grafts by 3 T magnetic resonance angiography (MRA) with respect to lumen visibility, susceptibility-induced signal loss, and type of stent artifacts compared with 1.5 T MRA in a phantom model. Six different stent-grafts (tube: n = 3, bifurcated: n = 3) were evaluated by 3 T and 1.5 T MRA using a tube phantom. MRA was performed using T1-weighted sequences at both systems with comparable parameters (3T: TR 5.4/TE 2.0/FA 30 degrees, 1.5 T: TR 6.2/TE 2.2/FA 30 degrees). A blind study of the image quality, including artifacts, was performed by 3 radiologists. Furthermore, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values were calculated. Statistical analysis was performed with Student's t test (P < 0.05). One Elgiloy stent graft showed almost a complete intraluminal signal loss at 1.5 and 3 T. All other models could be evaluated by both systems by MRA, resulting in a favorable lumen visibility (score: 1) for prostheses made of nitinol. Scores for overall image quality and artifacts were the same for both MR systems. SNR and CNR values of the stented part of the vessel phantom increased from 320 +/- 33 to 618 +/- 40 and from 306 +/- 34 to 596 +/- 40 at 3 T when compared with 1.5 T, resulting in a significant signal gain of 93% at the higher field strength. 3 Tesla MRA of aortic stent grafts in a phantom model demonstrates an increase in SNR and CNR when compared with 1.5 T. However, the magnitude of imaging artifacts as well as coherent intraluminal signal loss within the stent does not increase equally in both MR systems.Keywords
This publication has 28 references indexed in Scilit:
- Systematik der Artefakte metallischer Gefäßprothesen (Stents) in der MRTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological ImagingInvestigative Radiology, 2003
- Biomedical implants and devices: Assessment of magnetic field interactions with a 3.0‐Tesla MR systemJournal of Magnetic Resonance Imaging, 2002
- Wertigkeit der MRT in der Erkennung von Leckagen nach endovaskulärer AneurysmaausschaltungRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Application of magnetization transfer at 3.0 T in three‐dimensional time‐of‐flight magnetic resonance angiography of the intracranial arteriesJournal of Magnetic Resonance Imaging, 2002
- MR Angiographic Findings in Patients with Aortic EndoprosthesesAmerican Journal of Roentgenology, 2002
- High‐resolution intracranial and cervical MRA at 3.0T: Technical considerations and initial experienceMagnetic Resonance in Medicine, 2001
- MR Evaluation of Stent PatencyInvestigative Radiology, 2000
- Endoluminal Stent–Grafts for Infrarenal Abdominal Aortic AneurysmsNew England Journal of Medicine, 1997
- Effect of field strength on susceptibility artifacts in magnetic resonance imagingComputerized Medical Imaging and Graphics, 1990