Statistical dynamic image reconstruction in state-of-the-art high-resolution PET
- 4 October 2005
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (20) , 4887-4912
- https://doi.org/10.1088/0031-9155/50/20/010
Abstract
Modern high-resolution PET is now more than ever in need of scrutiny into the nature and limitations of the imaging modality itself as well as image reconstruction techniques. In this work, we have reviewed, analysed and addressed the following three considerations within the particular context of state-of-the-art dynamic PET imaging: (i) the typical average numbers of events per line-of-response (LOR) are now (much) less than unity, (ii) due to the physical and biological decay of the activity distribution, one requires robust and efficient reconstruction algorithms applicable to a wide range of statistics and (iii) the computational considerations in dynamic imaging are much enhanced (i.e., more frames to be stored and reconstructed). Within the framework of statistical image reconstruction, we have argued theoretically and shown experimentally that the sinogram non-negativity constraint (when using the delayed-coincidence and/or scatter-subtraction techniques) is especially expected to result in an overestimation bias. Subsequently, two schemes are considered: (a) subtraction techniques in which an image non-negativity constraint has been imposed and (b) implementation of random and scatter estimates inside the reconstruction algorithms, thus enabling direct processing of Poisson-distributed prompts. Both techniques are able to remove the aforementioned bias, while the latter, being better conditioned theoretically, is able to exhibit superior noise characteristics. We have also elaborated upon and verified the applicability of the accelerated list-mode image reconstruction method as a powerful solution for accurate, robust and efficient dynamic reconstructions of high-resolution data (as well as a number of additional benefits in the context of state-of-the-art PET).Keywords
This publication has 34 references indexed in Scilit:
- Emission Image Reconstruction for Randoms-Precorrected PET Allowing Negative Sinogram ValuesIEEE Transactions on Medical Imaging, 2004
- OS-EM and FBP reconstructions at low count rates: effect on 3D PET studies of [11C] WAY-100635NeuroImage, 2003
- Statistical approaches in quantitative positron emission tomographyStatistics and Computing, 2000
- Randoms variance reduction in 3D PETPhysics in Medicine & Biology, 1999
- Iterative algorithms for deblurring and deconvolution with constraintsInverse Problems, 1998
- Penalized weighted least-squares image reconstruction for positron emission tomographyIEEE Transactions on Medical Imaging, 1994
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Alternatives to voxels for image representation in iterative reconstruction algorithmsPhysics in Medicine & Biology, 1992
- Fast methods for including attenuation in the EM algorithmIEEE Transactions on Nuclear Science, 1990
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1986