An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation
- 1 January 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 15 (4) , 512-518
- https://doi.org/10.1109/42.511754
Abstract
An unbiased algorithm of generalized linear least squares (GLLS) for parameter estimation of nonuniformly sampled biomedical systems is proposed. The basic theory and detailed derivation of the algorithm are given. This algorithm removes the initial values required and computational burden of nonlinear least regression and achieves a comparable estimation quality in terms of the estimates' bias and standard deviation. Therefore, this algorithm is particular useful in image-wide (pixel-by-pixel based) parameter estimation, e.g., to generate parametric images from tracer dynamic studies with positron emission tomography. An example is presented to demonstrate the performance of this new technique. This algorithm is also generally applicable to other continuous system parameter estimation.Keywords
This publication has 17 references indexed in Scilit:
- A study on statistically reliable and computationally efficient algorithms for generating local cerebral blood flow parametric images with positron emission tomographyIEEE Transactions on Medical Imaging, 1993
- Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomographyInternational Journal of Bio-Medical Computing, 1993
- A Kinetic Evaluation of Blood—Brain Barrier Permeability in Human Brain Tumors with [68Ga]EDTA and Positron Computed TomographyJournal of Cerebral Blood Flow & Metabolism, 1984
- On the Construction of Functional Maps in Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1984
- Measurement of Cerebral Blood Flow Using Bolus Inhalation of C15O2 and Positron Emission Tomography: Description of the Method and its Comparison with the C15O2 Continuous Inhalation MethodJournal of Cerebral Blood Flow & Metabolism, 1984
- Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake DataJournal of Cerebral Blood Flow & Metabolism, 1983
- Measurement of Local Blood Flow and Distribution Volume with Short-Lived Isotopes: A General Input TechniqueJournal of Cerebral Blood Flow & Metabolism, 1982
- Identification of continuous-time multivariable systems from sampled data†International Journal of Control, 1982
- System identification via block-pulse functionsInternational Journal of Systems Science, 1981
- Dynamic Positron Emission Tomography for Study of Cerebral Hemodynamics in a Cross Section of the Head Using Positron-Emitting 68Ga-EDTA and 77KrJournal of Computer Assisted Tomography, 1977