Noninvasive Assessment of Local Pulse Pressure
- 1 July 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Hypertension
- Vol. 46 (1) , 244-248
- https://doi.org/10.1161/01.hyp.0000166723.07809.7e
Abstract
The advocated SphygmoCor procedure uses a radial-to-aorta transfer function with calibration on brachial instead of radial artery pressure to assess the central pulse pressure. We compared these values with carotid artery pulse pressures obtained from a validated calibration method, assuming mean minus diastolic blood pressure constant throughout the large artery tree. From 44 healthy subjects (21 males; 22 to 68 years) pressure waves were obtained at the radial, brachial, and carotid artery with applanation tonometry. Using the calibration method, radial and carotid artery pressures were assessed from brachial artery waves and pressures. The effect of brachial-to-radial pulse pressure amplification, brachial pulse pressure, mean pressure, age, gender, height, body mass index, and smoking on differences between the 2 methods was assessed. Brachial artery pressure was 118±12/72±10 mm Hg. SphygmoCor central pulse pressure was 9.7±4.6 mm Hg lower ( P P P =0.005). After calibration of the radial pressure wave with radial instead of brachial artery pressures, the difference between SphygmoCor central pulse pressure and carotid pulse pressure decreased with 4 mm Hg. The advocated SphygmoCor procedure systematically underestimates the central pulse pressure with brachial-to-radial pulse pressure amplification as important determinant. Therefore, calibration of radial artery pressure waves on brachial artery pressures should be avoided. The underestimation of central aortic pulse pressure caused by the radial-to-aorta transfer function itself is much less than previously reported.Keywords
This publication has 27 references indexed in Scilit:
- Clinical Utility of Aortic Pulses and Pressures Calculated From Applanated Radial-Artery PulsesHypertension, 2003
- Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressuresClinical Science, 2003
- Use of arterial transfer functions for the derivation of aortic waveform characteristicsJournal Of Hypertension, 2003
- Applicability and benefit of arterial transfer functionsJournal Of Hypertension, 2003
- Assessment of central arterial pressure?Journal Of Hypertension, 2003
- Pressure Wave Reflection Assessed From the Peripheral PulseHypertension, 2003
- Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressureJournal Of Hypertension, 2003
- How to assess central arterial blood pressure?Journal Of Hypertension, 2003
- Influence of drugs and gender on the arterial pulse wave and natriuretic peptide secretion in untreated patients with essential hypertensionClinical Science, 2002
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986