A selective and sensitive high performance liquid chromatographic (HPLC) method has been developed for the determination of reduced glutathione (GSH) in biological samples (rat liver, spleen and plasma). The method involved a prechromatographic thiol derivatization with methyl 4‐(6‐methoxynaphthalen‐2‐yl)‐4‐oxo‐2‐butenoate; the reaction was rapid (5 min) under mild conditions (pH 7.5 and ambient temperature) and selective for the sulphydryl group. The thiol adducts were separated on a reversed‐phase C‐18 column using acetonitrile: 0.05 M triethylammonium (TEA) phosphate (pH 4) solution 32:68 (v/v) as the mobile phase. Fluorescence detection (λem = 450 nm; λexc = 310 nm) was used and the detection limit (S/N = 3) was about 0.5 pmole of the injected GSH adduct. The method was also applied to the determination of total glutathione in rat plasma after a preliminary reduction with dithiothreitol.Keywords
This publication has 18 references indexed in Scilit:
- Glutathione and cysteine measurement in biological samples by HPLC with a glassy carbon working detectorBiomedical Chromatography, 1994
- Thin-Layer Chromatography of Aliphatic Thiols After Fluorescent Labelling with Methyl 4-(6-Methoxynaphthalen-2-yl)-4-oxo-2-butenoateJournal of Liquid Chromatography, 1993
- Rapid liquid chromatographic assay of glutathione in cultured cellsBiomedical Chromatography, 1993
- Packed capillary liquid chromatography coupled to fluorescence detection: Application to human blood samples for the determination of glutathioneJournal of Pharmaceutical and Biomedical Analysis, 1992
- Determination of reduced glutathione in human whole blood by high-performance liquid chromatography with electrochemical detection by a graphite-epoxy resin electrode chemically modified with cobalt phthalocyanineTalanta, 1991
- The simultaneous determination of oxidized and reduced glutathiones in liver tissue by ion pairing reverse phase high performance liquid chromatography with a coulometric electrochemical detectorClinica Chimica Acta; International Journal of Clinical Chemistry, 1989
- Fluorogenic reagent for thiols: 4-(N,N-dimethylaminosulphonyl)-7-fluoro-2,1,3-benzoxadiazoleThe Analyst, 1989
- Glutathione, free radicals and chemotherapeutic agentsPharmacology & Therapeutics, 1988
- Measurement of Tissue Sulfhydryls and Disulfides in Tissue Protein and Nonprotein Fractions by High Performance Liquid Chromatography Using Electrochemical DetectionJournal of Liquid Chromatography, 1987
- Selective Modification of Glutathione MetabolismScience, 1983