Abstract
Background: We explored the potential of a microfluidic device based on centrifugal force as an immunoassay platform by examining the imprecision of assays carried out with 200 nL of sample. Methods: Biotinylated antibodies against α-fetoprotein (AFP), interleukin-6 (IL-6), and carcinoembryonic antigen [(CEA); 0.1 g/L each in 15 mmol/L phosphate-buffered saline (PBS) containing 0.1 mL/L Tween 20] were attached to a microcolumn packed with streptavidin-coated particles. A 200-nL sample was then allowed to pass through the microcolumn for 240 s, followed by Alexa 647–labeled detection antibody (7.5 mg/L in 15 mmol/L PBS containing 10 g/L bovine serum albumin). The flow rate was controlled by altering the rotational speed. Up to 104 sandwich type immunoassays were completed within 50 min. Results: For AFP, IL-6, and CEA the detection limits were, respectively, 0.15, 1.25, and 1.31 pmol/L. Inter- and intraassay imprecisions (CVs) were Conclusions: Day-to-day (total) imprecision (CV) of immunoassays on the compact disc–shaped device are <20%. Analysis of fluorescence images allows rapid ranking of antibodies according to their affinities.Keywords
This publication has 15 references indexed in Scilit:
- Investigation into the Applicability of the Centrifugal Microfluidics Platform for the Development of Protein−Ligand Binding Assays Incorporating Enhanced Green Fluorescent Protein as a Fluorescent ReporterAnalytical Chemistry, 2004
- Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic AssaysAnalytical Chemistry, 1999
- Fiber Optic Imaging SensorsAccounts of Chemical Research, 1998
- Recognition of Electron-Donating Guests by Carborane-Supported Multidentate Macrocyclic Lewis Acid Hosts: Mercuracarborand ChemistryAccounts of Chemical Research, 1997
- Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensorsCurrent Opinion in Biotechnology, 1997
- The resonant mirror: a novel optical biosensor for direct sensing of biomolecular interactions Part I: Principle of operation and associated instrumentationBiosensors and Bioelectronics, 1993
- Micromachining of monocrystalline silicon and glass for chemical analysis systems A look into next century's technology or just a fashionable craze?TrAC Trends in Analytical Chemistry, 1991
- Light-Directed, Spatially Addressable Parallel Chemical SynthesisScience, 1991
- Frequency of a quartz microbalance in contact with liquidAnalytical Chemistry, 1985
- An immunospecific microbalanceJournal of Biomedical Materials Research, 1972