Predictive value of measurements of respiratory mechanics in preterm infants with HMD
- 1 August 1993
- journal article
- Published by Wiley in Pediatric Pulmonology
- Vol. 16 (2) , 116-123
- https://doi.org/10.1002/ppul.1950160207
Abstract
Conventional methods for measuring respiratory mechanics model the respiratory system as a single compartment. The interrupter technique allows the respiratory system to be considered as a two compartment model with “flow resistance” of the conducting airways (Pinit), calculated from the initial pressure drop (Pinit), considered separately from Pdiff, as a measure of the viscoelastic properties of the lung and chest wall and any pendelluft present. The pulmonary mechanics of 50 intubated and mechanically ventilated preterm infants (≤1500 g) were studied during the first week of life using conventional methods and the interrupter technique to determine whether it was possible to predict which infants would develop bronchopulmonary dysplasia (BPD). Pulmonary mechanics of preterm infants intubated and ventilated for apnea of prematurity were also studied. The dynamic compliance of the respiratory system (Crsdyn) was significantly lower on day 1 (PPrs), Rinit, or Pdiff between BPD and no‐BPD groups. However, Pdiff was significantly higher in infants with HMD, regardless of the outcome, when compared to the infants ventilated for apnea of prematurity. This suggests that the pathology of HMD is distal to the conducting airways and significantly alters the viscoelastic properties of the lung on day 1. Using stepwise logistic regression, Crsdum on day 1 and birth weight or gestational age were significant independent predictors of the development of BPD, correctly classifying 92% of infants. Due to the correlation between birth weight and gestational age (r = 0.72, Prsdyn is a better independent predictor of the development of BPD in preterm infants with HMD than gestational age or birth weight. Pediatr Pulmonol. 1993; 16:116–123.Keywords
This publication has 19 references indexed in Scilit:
- Effect of pulmonary blood flow on measurements of respiratory mechanics using the interrupter techniqueJournal of Applied Physiology, 1993
- Relative likelihood of bronchopulmonary dysplasia based on pulmonary mechanics measured in preterm neonates during the first week of lifeThe Journal of Pediatrics, 1992
- Non-invasive determination of alveolar pressure during mechanical ventilationEuropean Respiratory Journal, 1991
- Computer analysis of physical factors affecting the use of the interrupter technique in infantsPediatric Pulmonology, 1988
- Compliance measurement in respiratory distress syndrome: The prediction of outcomePediatric Pulmonology, 1986
- The accuracy of esophageal pressure measurements in convalescent and sick intubated infantsPediatric Pulmonology, 1986
- Pulmonary compliance in sick low birthweight infants. How reliable is the measurement of oesophageal pressure?Archives of Disease in Childhood, 1983
- Early prediction of chronic lung disease by pulmonary function testingThe Journal of Pediatrics, 1983
- Kinetic energy loss and convective acceleration in respiratory resistance measurementsLung, 1979
- Pulmonary Disease Following Respirator Therapy of Hyaline-Membrane DiseaseNew England Journal of Medicine, 1967