Determination of functional residual capacity by oxygen washin-washout: a validation study
- 15 March 2007
- journal article
- clinical trial
- Published by Springer Nature in Intensive Care Medicine
- Vol. 33 (5) , 912-916
- https://doi.org/10.1007/s00134-007-0578-2
Abstract
To validate a new system for functional residual capacity (FRC) measurements using oxygen washin/washout in spontaneously breathing humans. The system (LUFU, Drägerwerk AG, Lübeck, Germany) consists of an unmodified EVITA 4 ventilator, a side-stream paramagnetic oxygen sensor and a dedicated software. Laboratory study and measurements in spontaneously breathing volunteers. Pulmonary function laboratory of a university hospital. 20 healthy and 15 lung diseased volunteers. FRC was measured by LUFU (LUFU-FRC) and by helium dilution (He-FRC); intra-thoracic gas volume (ITGV) was determined by body plethysmography. Each measurement cycle consisted of four independent LUFU-FRC determinations (step change of FiO2 from 0.21 to 0.5 and back and from 0.21 to 1.0 and back), two helium-dilution runs and two body box measurements. Repeatability and agreement between methods were determined by comparing different measurements of one technique and by comparing different techniques among each other. Repeatability of LUFU-FRC was estimated by comparing washin to washout and the different FiO2steps. The difference of the means was 3.7% at the most. Agreement between methods resulted in the following differences (mean ± standard deviation of differences) for healthy and lung-diseased volunteers, respectively: LUFU-FRC vs. He-FRC –0.40 ± 0.50 L (0.02 ± 0.95 L), LUFU-FRC vs. ITGV –0.43 ± 0.54 L (–0.18 ± 0.61 L) and He-FRC vs. ITGV –0.03 ± 0.43 L (–0.20 ± 0.98 L). LUFU is a non-invasive method for the determination of FRC that requires only minor additional equipment and no modification to the ventilator. It can be used in difficult conditions such as breathing patterns with variations from breath to breath. The results of this study show that LUFU is sufficiently reliable and repeatable to warrant its clinical application.Keywords
This publication has 20 references indexed in Scilit:
- Monitoring of Functional Residual Capacity by an Oxygen Washin/Washout; Technical Description and EvaluationJournal of Clinical Monitoring and Computing, 2006
- Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen FractionAnesthesia & Analgesia, 2005
- Determination of functional residual capacity (FRC) by multibreath nitrogen washout in a lung model and in mechanically ventilated patientsIntensive Care Medicine, 1998
- The recording of FRC — is it of importance and can it be made simple?Intensive Care Medicine, 1993
- Lung volumes and forced ventilatory flowsEuropean Respiratory Journal, 1993
- Measurement of Lung Volume by Sulfur Hexafluoride Washout during Spontaneous and Controlled VentilationAnesthesiology, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Variability of routine pulmonary function tests.Thorax, 1975
- Determination of Functional Residual Capacity during Mechanical VentilationAnesthesiology, 1974
- Accuracy and Precision of Helium Dilution Technique and Body Plethysmography in Measuring Lung VolumesScandinavian Journal of Clinical and Laboratory Investigation, 1973