Radiation dose estimate in small animal SPECT and PET
- 27 August 2004
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (9) , 2680-2686
- https://doi.org/10.1118/1.1781553
Abstract
Calculations of radiation dose are important in assessing the medical and biological implications of ionizing radiation in medical imaging techniques such as SPECT and PET. In contrast, radiation dose estimates of SPECT and PET imaging of small animals are not very well established. For that reason we have estimated the whole-body radiation dose to mice and rats for isotopes such as 18F, 99mTc, 201Tl, (111)In, 123I, and 125I that are used commonly for small animal imaging. We have approximated mouse and rat bodies with uniform soft tissue equivalent ellipsoids. The mouse and rat sized ellipsoids had a mass of 30 g and 300 g, respectively, and a ratio of the principal axes of 1:1:4 and 0.7:1:4. The absorbed fractions for various photon energies have been calculated using the Monte Carlo software package MCNP. Using these values, we then calculated MIRD S-values for two geometries that model the distribution of activity in the animal body: (a) a central point source and (b) a homogeneously distributed source, and compared these values against S-value calculations for small ellipsoids tabulated in MIRD Pamphlet 8 to validate our results. Finally we calculated the radiation dose taking into account the biological half-life of the radiopharmaceuticals and the amount of activity administered. Our calculations produced S-values between 1.06 x 10(-13) Gy/Bq s and 2.77 x 10(-13) Gy/Bq s for SPECT agents, and 15.0 x 10(-13) Gy/Bq s for the PET agent 18F, assuming mouse sized ellipsoids with uniform source distribution. The S-values for a central point source in an ellipsoid are about 10% higher than the values obtained for the uniform source distribution. Furthermore, the S-values for mouse sized ellipsoids are approximately 10 times higher than for the rat sized ellipsoids reflecting the difference in mass. We reviewed published data to obtain administered radioactivity and residence times for small animal imaging. From these values and our computed S-values we estimated that the whole body dose in small animals ranges between 6 cGy and 90 cGy for mice and between about 1 cGy and 27 cGy for rats. The whole body dose in small animal imaging can be very high in comparison to the lethal dose to mice (LD50/30 approximately 7 Gy). For this reason the dose in small animal imaging should be monitored carefully and the administered activity should be kept to a minimum. These results also underscore the need of further development of instrumentation that improves detection efficiency and reduces radiation dose in small animal imaging.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health (8 R01 EB00348)
This publication has 12 references indexed in Scilit:
- In Vivo Quantitative Noninvasive Imaging of Gene Transfer by Single-Photon Emission Computerized TomographyHuman Gene Therapy, 2003
- Radioprotection of Swiss Albino Mice by Plant Extract Mentha piperita(Linn.).Journal of Radiation Research, 2003
- Nuclear medicine applications in molecular imagingJournal of Magnetic Resonance Imaging, 2002
- Towards in vivo nuclear microscopy: iodine-125 imaging in mice using micro-pinholesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Induction of Gene Expression as a Monitor of Exposure to Ionizing RadiationRadiation Research, 2001
- Imaging Transgenic AnimalsAnnual Review of Biomedical Engineering, 1999
- Pharmacokinetics of 111In-labelled monoclonal antibody ZCE-025 and fragments in tumour-bearing miceNuclear Medicine Communications, 1995
- Postirradiation treatment with granulocyte colony-stimulating factor and preirradiation WR-2721 administration synergize to enhance hemopoietic reconstitution and increase survivalInternational Journal of Radiation Oncology*Biology*Physics, 1992
- A preliminary pharmacokinetic study of 111In-labeled 260F9 anti-(breast cancer) antibody in patientsCancer Immunology, Immunotherapy, 1989