Estimation of labeling efficiency in pseudocontinuous arterial spin labeling
Top Cited Papers
Open Access
- 25 February 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 765-771
- https://doi.org/10.1002/mrm.22245
Abstract
Pseudocontinuous arterial spin labeling MRI is a new arterial spin labeling technique that has the potential of combining advantages of continuous arterial spin labeling and pulsed arterial spin labeling. However, unlike continuous arterial spin labeling, the labeling process of pseudocontinuous arterial spin labeling is not strictly an adiabatic inversion and the efficiency of labeling may be subject specific. Here, three experiments were performed to study the labeling efficiency in pseudocontinuous arterial spin labeling MRI. First, the optimal labeling position was determined empirically to be approximately 84 mm below the anterior commissure‐posterior commissure line in order to achieve the highest sensitivity. Second, an experimental method was developed to utilize phase‐contrast velocity MRI as a normalization factor and to estimate the labeling efficiency in vivo, which was founded to be 0.86 ± 0.06 (n = 10, mean ± standard deviation). Third, we compared the labeling efficiency of pseudocontinuous arterial spin labeling MRI under normocapnic and hypercapnic (inhalation of 5% CO2) conditions and showed that a higher flow velocity in the feeding arteries resulted in a reduction in the labeling efficiency. In summary, our results suggest that labeling efficiency is a critical parameter in pseudocontinuous arterial spin labeling MRI not only in terms of achieving highest sensitivity but also in quantification of absolute cerebral blood flow in milliliters per minute per 100 g. We propose that the labeling efficiency should be estimated using phase‐contrast velocity MRI on a subject‐specific basis. Magn Reson Med 63:765–771, 2010.Keywords
Funding Information
- National Institutes of Health (R01 MH084021, R21 NS054916, R21 EB007821, R21 AG034318, R01 AG033106)
- Texas Instruments Foundation, Department of Veterans Affairs (VA549P0027)
This publication has 27 references indexed in Scilit:
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labelingMagnetic Resonance in Medicine, 2007
- Vessel‐encoded arterial spin‐labeling using pseudocontinuous taggingMagnetic Resonance in Medicine, 2007
- Determining the longitudinal relaxation time (T1) of blood at 3.0 TeslaMagnetic Resonance in Medicine, 2004
- Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: A computer simulationMagnetic Resonance in Medicine, 2004
- Measurements of cerebral perfusion and arterial hemodynamics during visual stimulation using TURBO‐TILTMagnetic Resonance in Medicine, 2003
- Sickle Cell Disease: Continuous Arterial Spin-labeling Perfusion MR Imaging in ChildrenRadiology, 2003
- Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2002
- Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivoMagnetic Resonance in Medicine, 1989
- What is the Correct Value for the Brain-Blood Partition Coefficient for Water?Journal of Cerebral Blood Flow & Metabolism, 1985