Comparative Evaluation of Bipolar Atrial Electrogram Amplitude During Everyday Activities: Atrial Active Fixation Versus Two Types of Single Pass VDD/R Leads
- 1 November 1994
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (11) , 1873-1877
- https://doi.org/10.1111/j.1540-8159.1994.tb03766.x
Abstract
Endocardial P wave amplitude (PWA) is an important determinant of the atrial sensing capabilities of an atrial-based pacing system. Although changes in PWA during physical activities are known to occur in DDD/R pacing, there is little information on the P wave stability in single pass lead VDD/R pacemakers using floating P wave sensing. We investigated the variation of PWA during daily life activities using telemetry recorded atrial electrograms in 21 patients with DDDR pacemakers (Relay or Elite) and 29 patients with single lead VDD/R pacemakers (Unity or Thera). Physical activities resulted in marked individual variability of PWA but, as a group, there was no significant difference between PWA during sitting, standing, lying down, and coughing in both DDDR and VDD/R pacing. In the Elite II pacemaker, walking at 2 miles per hour resulted in significant reduction of PWA (11.6% compared with sitting, P < 0.05). The most consistent reduction in PWA occurred in the relaxation phase of the Valsalva maneuver (VM), with all pacemakers showing a reduction in PWA (mean reduction in PWA compared with sitting in DDDR and VDD/R were 16.6% and 12.8%, respectively). Two patients with DDDR pacemakers (Relay) and three patients with VDD/R pacemakers (1 Unity and 2 Thera) had atrial sensing failure during VM or walking. In conclusion, large variation in PWA occurs during daily life activities. The extent of variation is dependent on the patients, types of atrial lead, and the maneuvers performed. A twice sensing threshold may be insufficient to ensure adequate atrial sensing during these activities.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 8 references indexed in Scilit:
- Atrial sensing performance of the single-lead VDD pacemaker during exerciseJournal of the American College of Cardiology, 1993
- The Effect of Exercise on the Atrial Electrogram Voltage in Young PatientsPacing and Clinical Electrophysiology, 1991
- Superior Cardiac Hemodynamics of Atrioventricular Synchrony Over Rate Responsive Pacing at Submaximal Exercise: Observations in Activity Sensing DDDR PacemakersPacing and Clinical Electrophysiology, 1990
- Physical Determinants of the Endocardial P WavePacing and Clinical Electrophysiology, 1990
- Atrial signal variations and pacemaker malsensing during exercise: A study in the time and frequency domainJournal of the American College of Cardiology, 1988
- Atrial Sensing Performance of AV Universal Pacemakers During ExercisePacing and Clinical Electrophysiology, 1988
- A Theoretical Right Atrial Pressure Feedback Heart Rate Control System to Restore Physiologic Control to the Rate‐limited HeartPacing and Clinical Electrophysiology, 1984
- Arrhythmias of Dual Chamber PacemakersPacing and Clinical Electrophysiology, 1982