Treatment of 14 intracranial aneurysms with the FRED system
- 5 September 2013
- journal article
- new devices
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 6 (8) , 614-617
- https://doi.org/10.1136/neurintsurg-2013-010917
Abstract
Background Endovascular treatment of intracranial aneurysms via flow diversion has become increasingly popular over the past several years. The flow redirection endoluminal device (FRED; Microvention, Tustin, California, USA) system is a next generation closed cell paired stent flow diversion device. Objective Our initial clinical experience with the FRED system is described. We believe this series to be the first use of the FRED system in the western hemisphere. Methods 14 aneurysms were treated utilizing the FRED system in 13 patients. Post-deployment angiography and fluoro CTs were obtained in all cases. Results Immediate post-treatment angiography demonstrated reduced flow into all aneurysms although no long term angiographic data are yet available. The device proved technically easy to deploy and recapture after partial deployment if needed. No complications, technical or otherwise, were encountered. Radiographic visibility and ability to maintain its internal cylindrical shape in tortuous arteries, as demonstrated by fluoro CT, was at least as good as the pipeline embolization device. Conclusions The FRED system was technically easy to deploy with no procedural complications occurring in this first reported series of 14 aneurysms. The ability of the FRED system to be recaptured after partial deployment and to maintain its internal shape in tortuous vessels was demonstrated well. Long term clinical and angiographic follow-up along with prospective studies are now needed to ascertain the role of the FRED in intracranial aneurysm treatment.Keywords
This publication has 16 references indexed in Scilit:
- Intracranial Aneurysms: Midterm Outcome of Pipeline Embolization Device—A Prospective Study in 143 Patients with 178 AneurysmsRadiology, 2012
- Long-Term Follow-Up after Treatment of Intracranial Aneurysms with the Pipeline Embolization Device: Results from a Single CenterAmerican Journal of Neuroradiology, 2011
- Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2011
- Flow Diversion for Intracranial Aneurysms: Optimally Defining and Evolving a New Tool and ApproachWorld Neurosurgery, 2011
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysmsJournal of NeuroInterventional Surgery, 2009
- CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- DEFINITIVE RECONSTRUCTION OF CIRCUMFERENTIAL, FUSIFORM INTRACRANIAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2008
- Endovascular Reconstruction with the Neuroform Stent as Monotherapy for the Treatment of Uncoilable Intradural PseudoaneurysmsNeurosurgery, 2006