The effect of dose calculation accuracy on inverse treatment planning
- 17 January 2002
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 47 (3) , 391-407
- https://doi.org/10.1088/0031-9155/47/3/303
Abstract
The effect of dose calculation accuracy during inverse treatment planning for intensity modulated radiotherapy (IMRT) was studied in this work. Three dose calculation methods were compared: Monte Carlo, superposition and pencil beam. These algorithms were used to calculate beamlets, which were subsequently used by a simulated annealing algorithm to determine beamlet weights which comprised the optimal solution to the objective function. Three different cases (lung, prostate and head and neck) were investigated and several different objective functions were tested for their effect on inverse treatment planning. It is shown that the use of inaccurate dose calculation introduces two errors in a treatment plan, a systematic error and a convergence error. The systematic error is present because of the inaccuracy of the dose calculation algorithm. The convergence error appears because the optimal intensity distribution for inaccurate beamlets differs from the optimal solution for the accurate beamlets. While the systematic error for superposition was found to be ~1% of Dmax in the tumour and slightly larger outside, the error for the pencil beam method is typically ~5% of Dmax and is rather insensitive to the given objectives. On the other hand, the convergence error was found to be very sensitive to the objective function, is only slightly correlated to the systematic error and should be determined for each case individually. Our results suggest that because of the large systematic and convergence errors, inverse treatment planning systems based on pencil beam algorithms alone should be upgraded either to superposition or Monte Carlo based dose calculations.Keywords
This publication has 29 references indexed in Scilit:
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- The effect of statistical uncertainty on inverse treatment planning based on Monte Carlo dose calculationPhysics in Medicine & Biology, 2000
- The impact of electron transport on the accuracy of computed doseMedical Physics, 2000
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999
- Monte Carlo-based inverse treatment planningPhysics in Medicine & Biology, 1999
- A CT‐based Monte Carlo simulation tool for dosimetry planning and analysisMedical Physics, 1998
- 3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC)Medical Physics, 1996
- Accounting for primary electron scatter in x-ray beam convolution calculationsMedical Physics, 1995
- Calculation and Application of Point Spread Functions for Treatment Planning with High Energy Photon BeamsActa Oncologica, 1987
- A photon dose distribution model employing convolution calculationsMedical Physics, 1985