Improving calibration accuracy in gel dosimetry
- 1 October 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (10) , 2709-2720
- https://doi.org/10.1088/0031-9155/43/10/002
Abstract
A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum , and the other to 4.5 Gy at . The new calibration method is compared with a `standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of and an intercept of Gy. For higher doses, nonlinear behaviour was observed.Keywords
This publication has 6 references indexed in Scilit:
- An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetryPhysics in Medicine & Biology, 1998
- Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetryPhysics in Medicine & Biology, 1998
- Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of bang polymer gel dosimetersInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Radiation therapy dosimetry using magnetic resonance imaging of polymer gelsMedical Physics, 1996
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRIMagnetic Resonance Imaging, 1993