Randomized comparison of cognitive function in humans at 0 and 8 Tesla
- 18 August 2003
- journal article
- clinical trial
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (3) , 342-345
- https://doi.org/10.1002/jmri.10366
Abstract
Purpose To discover whether there was a measurable alteration in cognitive performance in humans when exposed to a static magnetic field of 8 Tesla (T). Materials and Methods Twenty‐five normal human subjects were evaluated at both 0.05 and 8 T in a randomized order. Six standardized neuropsychological tests were administered and auditory reaction times were assessed. The cognitive assessment included measures of learning and retention, verbal fluency (spontaneous word generation), auditory attention, and auditory working memory. Alternate test forms were utilized to reduce practice effects. The sequential order of testing, 0.05 T first vs. 8 T first exposure, was randomized. The data was analyzed using univariate comparisons for correlated means to assess potential differences under the two conditions. Results There were no clinically significant differences in any of the measures. On a measure of recognition memory the subjects performed significantly better in the 0.05T condition, but the difference was extremely small, not clinically meaningful, and likely due to statistical artifact. Conclusion This study shows that exposure of the brain to high magnetic fields of up to 8 T does not appear to alter human cognitive performance. J. Magn. Reson. Imaging 2003;18:342–345.Keywords
This publication has 11 references indexed in Scilit:
- 8.0-Tesla human MR system: Temperature changes associated with radiofrequency-induced heating of a head phantomJournal of Magnetic Resonance Imaging, 2003
- High‐resolution, spin‐echo BOLD, and CBF fMRI at 4 and 7 TMagnetic Resonance in Medicine, 2002
- Effects of Exposure of CHO-K1 Cells to a 10-T Static Magnetic FieldRadiology, 2002
- Comparison of 1.5 and 8 Tesla High-Resolution Magnetic Resonance Imaging of Lacunar InfarctsJournal of Computer Assisted Tomography, 2002
- Auditory Noise Associated With MR Procedures: A ReviewJournal of Magnetic Resonance Imaging, 2000
- Subchronic In Vivo Effects of a High Static Magnetic Field (9.4 T) in RatsJournal of Magnetic Resonance Imaging, 2000
- Aneurysm Clips: Evaluation of Magnetic Field Interactions With an 8.0 T MR SystemJournal of Magnetic Resonance Imaging, 2000
- High Resolution MRI of the Deep Brain Vascular Anatomy at 8 Tesla: Susceptibility-Based Enhancement of the Venous StructuresJournal of Computer Assisted Tomography, 1999
- Magnetresonanztomographie und SicherheitRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1986
- Cognitive evaluation following NMR imaging of the brain.Journal of Neurology, Neurosurgery & Psychiatry, 1984