Evaluation of Nucleic Acid Amplification Tests in the Absence of a Perfect Gold-Standard Test
- 1 September 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Epidemiology
- Vol. 16 (5) , 604-612
- https://doi.org/10.1097/01.ede.0000173042.07579.17
Abstract
During the past 10 years, medical diagnostic testing for sexually transmitted infections (STIs) has changed markedly as a result of the rapid expansion and marketing of nucleic acid amplification tests (NAATs). Among such new DNA/RNA-amplification techniques are the polymerase chain reaction (PCR), the ligase chain reaction (LCR), and the transcription-mediated amplification (TMA) tests. Regrettably, the test evaluation process undergone by these tests has not always been rigorous or scientifically sound. Here, we review the controversy surrounding the statistical evaluation of these NAATs. We also review some of the traditional and recent statistical methods developed to estimate test sensitivity and specificity parameters in the absence of reliable gold-standard tests. In particular, we review the traditional latent class modeling approach that requires the assumption of independence between diagnostic tests conditional on the true disease status, and the more recent procedures that relax the conditional independence assumption. Finally, we apply some of these statistical modeling techniques to real data to estimate the sensitivity and specificity of a NAAT for Chlamydia trachomatis. On the basis of the latent class modeling approach with a pessimistic prior for culture sensitivity, the NAAT specificity estimate was 97.6% and, on the basis of an optimistic prior, the specificity was 95.3%. Similarly, the sensitivity estimates ranged from 88.1% to 89.6%.Keywords
This publication has 98 references indexed in Scilit:
- Clinical evaluation of the semiautomated BDProbeTec ET System for the detection of Mycobacterium tuberculosis in respiratory and nonrespiratory specimensDiagnostic Microbiology and Infectious Disease, 2004
- A Comparison of Bayesian and Maximum Likelihood Methods to Determine the Performance of a Point of Care Test for Helicobacter pylori in the Office SettingMedical Decision Making, 2003
- Accuracy of Results Obtained by Performing a Second Ligase Chain Reaction Assay and PCR Analysis on Urine Samples with Positive or Near-Cutoff Results in the LCx Test for Chlamydia trachomatisJournal of Clinical Microbiology, 2002
- Discrepant Analysis Is Still at LargeJournal of Clinical Microbiology, 2001
- A Model for Evaluating Sensitivity and Specificity for Correlated Diagnostic Tests in Efficacy Studies with an Imperfect Reference TestJournal of the American Statistical Association, 1998
- Evaluation of a new enzyme immunoassay (TESTPACK rotavirus) for the detection of rotavirus in fecal specimensDiagnostic Microbiology and Infectious Disease, 1988
- Comparison of a rapid latex agglutination assay and a fluorescent-antibody technique for the detection of herpes simplex antibodyDiagnostic Microbiology and Infectious Disease, 1988
- The Declining Specificity of Exercise Radionuclide VentriculographyNew England Journal of Medicine, 1983
- Methodology for the assessment of new dichotomous diagnostic testsJournal of Chronic Diseases, 1981
- Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic TestsNew England Journal of Medicine, 1978