SAR characteristics of three types of Contact Flexible Microstrip Applicators for superficial hyperthermia
- 1 January 1996
- journal article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 12 (2) , 255-269
- https://doi.org/10.3109/02656739609022513
Abstract
The Effective Field Sizes (EFS) and the Effective Heating Depths (EDH) of Contact Flexible Microstrip Applicators (CFMA), tuned at a frequency of 434 MHz, were determined on two fat/muscle phantoms. One phantom was box-shaped with a flat top layer of 1 cm thick artificial fat and the other one a tube of which the cross-section was elliptically shaped (25 x 36 cm) having a fat equivalent shell of 1 cm thick. For the muscle material a 6 g/l saline (NaCl) solution was used. On the flat rectangular phantom, the effective field size at 1 cm depth in saline was measured to be 4.7 x 13.5 cm, 17.5 x 17.7 cm and 12.5 x 14.0 cm for the 1H-applicator, the 3H-applicator and the 5H-applicator, respectively. For the 3H-and the 5H-applicator, the Specific absorption rate (SAR) distribution at 1 cm depth showed a single maximum of SAR for a thin bolus, which split into two separate "hot spots' for a thicker bolus. The Effective Heating Depths in the phantom with a flat surface were of the order of that of a plane wave (approximately 1.4 cm), whereas a larger EHD of 2.4 cm was achieved below the 3H-applicator bent to fit the elliptical phantom. Due to the large effective field size and the "flatness' of the SAR distribution, the applicators 3H and 5H are suitable to adequately treat large superficial tumours.Keywords
This publication has 15 references indexed in Scilit:
- Cartesian differential invariants in scale-spaceJournal of Mathematical Imaging and Vision, 1993
- 27 MHz hybrid evanescent-mode applicators (HEMA) with flexible heating field for deep and safe subcutaneous hyperthermiaInternational Journal of Hyperthermia, 1993
- Body conformable 915 MHz microstrip array applicators for large surface area hyperthermiaIEEE Transactions on Biomedical Engineering, 1992
- Current sheet applicator arrays for superficial hyperthermia of chestwall lesionsInternational Journal of Hyperthermia, 1992
- RTOG quality assurance guidelines for clinical trials using hyperthermiaInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Heating system with a lens applicator for 430 MHz microwave hyperthermiaInternational Journal of Hyperthermia, 1989
- Quality assurance guidelines for ESHO protocolsInternational Journal of Hyperthermia, 1989
- Quality-assurance reports: CDRH RF phantom for hyperthermia systems evaluationsInternational Journal of Hyperthermia, 1988
- Electromagnetic Applicators for Non-Invasive Local HyperthermiaPublished by Springer Nature ,1987
- Analyses of Electromagnetic Fields Induced in Biological Tissues by Thermographic Studies on Equivalent Phantom ModelsIEEE Transactions on Microwave Theory and Techniques, 1971