Rapid Quantification of Hepatitis B Virus DNA by Automated Sample Preparation and Real-Time PCR
- 1 June 2004
- journal article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 42 (6) , 2445-9
- https://doi.org/10.1128/jcm.42.6.2445-2449.2004
Abstract
Monitoring of hepatitis B virus (HBV) DNA in serum by molecular methods has become the standard for assessment of the replicative activity of HBV. Several molecular assays for the detection and quantification of HBV DNA have been described. However, they usually lack automated sample preparation. Moreover, those assays, which are based on PCR, are limited by a short dynamic range (2 to 3 log units). In the present study, the use of RealArt HBV LC PCR Reagents in conjunction with automated extraction on the COBAS AMPLIPREP analyzer was evaluated. Members of an HBV proficiency program panel were tested; linearity, interassay, and intra-assay variations were determined. The performance of the assay in a routine clinical laboratory was evaluated with a total of 117 clinical specimens. When members of the HBV proficiency program panel were tested by the new molecular assay, the results were found to be within +/-0.5 log unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve over more than 6 log units. The interassay variation of the RealArt HBV LC PCR Reagents by use of the automated sample preparation protocol ranged from 16 to 73%, and the intra-assay variation ranged from 9 to 40%. When clinical samples were tested by the new assay with the automated sample preparation protocol and the results were compared with those obtained by the COBAS AMPLICOR HBV MONITOR Test with manual sample preparation, the results for 76% of all samples with positive results by both tests were found to be within +/-0.5 log unit and the results for another 18% were found to be within between 0.5 and 1.0 log unit. In conclusion, the real-time PCR assay with automated sample preparation proved to be suitable for the routine molecular laboratory and required less hands-on time.Keywords
This publication has 11 references indexed in Scilit:
- Detection of serum hepatitis B virus DNA by real-time quantitative polymerase chain reaction (TaqMan PCR) during lamivudine treatment: comparison with three other assaysHepatology Research, 2003
- Rapid quantification of hepatitis B virus DNA by real-time PCR using fluorescent hybridization probesJournal of Medical Microbiology, 2003
- Evaluation of an Automated Sample Preparation Protocol for Quantitative Detection of Hepatitis C Virus RNAJournal of Clinical Microbiology, 2002
- Comparative Evaluation of Semiautomated COBAS AMPLICOR Hepatitis B Virus (HBV) MONITOR Test and Manual Microwell Plate-Based AMPLICOR HBV MONITOR TestJournal of Clinical Microbiology, 2001
- Automation of laboratory testing for infectious diseases using the polymerase chain reaction — our past, our present, our futureJournal of Clinical Virology, 2001
- The role of viral load determination for the management of human immunodeficiency virus, hepatitis B virus and hepatitis C virus infectionJournal of Clinical Virology, 2001
- Semiautomated Quantification of Hepatitis B Virus DNA in a Routine Diagnostic LaboratoryClinical and Diagnostic Laboratory Immunology, 2000
- Identification of Different States of Hepatitis B Virus Infection with a Quantitative PCR AssayClinical and Diagnostic Laboratory Immunology, 2000
- Automated Quantitative Analysis of Hepatitis B Virus DNA by Using the Cobas Amplicor HBV Monitor TestJournal of Clinical Microbiology, 1999
- Quantitation of HBV DNA in Human Serum Using a Branched DNA (bDNA) Signal Amplification AssayAmerican Journal of Clinical Pathology, 1995