In vitro validation of phase‐contrast flow measurements at 3 T in comparison to 1.5 T: Precision, accuracy, and signal‐to‐noise ratios
Open Access
- 15 April 2005
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (5) , 604-610
- https://doi.org/10.1002/jmri.20275
Abstract
Purpose To evaluate the signal‐to‐noise ratio (SNR), precision, and accuracy of phase‐contrast flow measurements at 3 T with the help of an in vitro model and to compare the results with data from two 1.5‐T scanners. Materials and Methods Using an identical setup of a laminar flow model and sequence parameters, measurements were done at one 3‐T and at two 1.5‐T systems. Precision, accuracy, and SNR were obtained for velocity encodings ranging from 55 up to 550 cm−1. SNRs were calculated from the magnitude as well as the flow encoded images. Results Precision and accuracy for the in vitro flow model were similarly high in all scanners with no significant difference. For velocity encodings from 55 cm−1 up to 550 cm−1, the SNR in magnitude as well as phase encoded images of the 3‐T measurements was approximately 2.5 times higher than the SNR obtained from the two 1.5‐T systems. Conclusion Even without optimization for the 3‐T environment, flow measurements show the same high accuracy and precision as is known from clinical 1.5‐T scanners. The superior SNR at 3 T will allow further improvements in temporal and spatial resolution. This will be of interest for small‐size vessels like coronary arteries or for slow diastolic flow patterns. J. Magn. Reson. Imaging 2005;21:604–610.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (DFG) (Fe 206/8-1-723/01)
This publication has 25 references indexed in Scilit:
- Comparison of Cardiac MRI on 1.5 and 3.0 Tesla Clinical Whole Body SystemsInvestigative Radiology, 2003
- High-resolution MR imaging of the knee at 3 TActa Radiologica, 2000
- Comparative Assessment of Right Ventricular Volumes and Ejection Fraction by Thermodilution and Magnetic Resonance Imaging in Dilated CardiomyopathyCardiology, 1995
- Magnetic Resonance Imaging of Blood Flow with a Phase Subtraction TechniqueInvestigative Radiology, 1993
- Visualization and quantification of the human blood flow by magnetic resonance imagingJournal of Biomechanics, 1992
- Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiographyJournal of Magnetic Resonance Imaging, 1991
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991
- An evaluation of the accuracy of flow measurements using magnetic resonance imaging (MRI)Journal of Medical Engineering & Technology, 1991
- Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsetsMagnetic Resonance in Medicine, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986