Monte Carlo study of grid performance in diagnostic radiology: factors which affect the selection of tube potential and grid ratio
- 1 December 1993
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 66 (792) , 1164-1176
- https://doi.org/10.1259/0007-1285-66-792-1164
Abstract
A Monte Carlo computational model has been developed for the study of the performance of anti-scatter grids in diagnostic radiology. It is used here to estimate the scatter in the image plane from soft tissue phantoms (representing the patient) and to calculate image contrast and the mean absorbed dose in the phantom. Different scattering conditions, representative of various examinations, have been investigated: adult lumbar spine; small field radiography and fluoroscopy; adult chest and paediatric pelvis and chest. For each scattering condition, the combinations of tube potential and grid ratio have been found which, for a well designed grid, result in the lowest mean absorbed dose in the phantom for a fixed contrast level. In examinations which generate large amounts of scatter, the use of high grid ratios in combination with high tube potentials is favourable with regard to both mean absorbed dose in the phantom and tube charge. When less scatter is generated, either the grid ratio or the tube potential can be varied to achieve the desired contrast level. High grid ratios require shorter exposure times, but need careful alignment in the beam to prevent primary radiation cut-off. It is shown that the air gap technique can be used to reduce patient dose in examinations with small amounts of scatter, but in combinations with a lower tube potential than when a grid is used.Keywords
This publication has 23 references indexed in Scilit:
- Monte Carlo study of grid performance in diagnostic radiology: task dependent optimization for screen–film imagingThe British Journal of Radiology, 1994
- Selection of anti-scatter grids for different imaging tasks: the advantage of low atomic number cover and interspace materialsThe British Journal of Radiology, 1993
- Doses to patients from routine diagnostic X-ray examinations in EnglandThe British Journal of Radiology, 1986
- Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinationsMedical Physics, 1984
- Investigation of the performance of antiscatter grids: Monte Carlo simulation studiesPhysics in Medicine & Biology, 1982
- Calculation of X-ray grid characteristics by Monte Carlo methodsPhysics in Medicine & Biology, 1982
- A method for testing scattered radiation gridsMedical Physics, 1980
- Quality and Choice of Potter Bucky Grids Parts IV and VActa Radiologica, 1961