Utilization of Pipeline embolization device for treatment of ruptured intracranial aneurysms: US multicenter experience
- 18 September 2014
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 7 (11) , 808-815
- https://doi.org/10.1136/neurintsurg-2014-011320
Abstract
Objective Utilization of the Pipeline embolization device (PED) in complex ruptured aneurysms has not been well studied. We evaluated the safety and effectiveness data from five participating US centers. Methods Records of patients with ruptured cerebral aneurysms who underwent PED treatment between 2011 and 2013 were retrospectively reviewed. Results 26 patients with ruptured aneurysms underwent PED treatment (mean age 51.4±13.2 years;16 women). At presentation, 8 patients (30.8%) had a Hunt–Hess grade of IV or above; 11 required extraventricular drain placement. Aneurysm morphologies were: 8 dissecting, 8 blister-like, 6 fusiform, and 4 saccular. There were 22 anterior circulation and 4 posterior circulation aneurysms. PED deployment was successful in all patients, with adjunctive coiling utilized in 12. Periprocedural complications occurred in 5 (19.2%), including 3 inhospital deaths. 23 patients (88.5%) had postoperative angiography at a mean of 5.9 months: 18 aneurysms (78.3%) were completely occluded, 3 (13.0%) had residual neck filling, and 2 (8.7%) had residual dome filling. All blister-type aneurysms were completely occluded at follow-up. Clinical follow-up was available for an average of 10.1 months (range 2–21 months), with one asymptomatic in-stent stenosis and one asymptomatic thromboembolic stroke noted. Good outcome (modified Rankin Scale (mRS) score of 0–2) was achieved in 20 patients (76.9%), fair (mRS 3–4) in 3 (11.5%), and 3 died (11.5%). Conclusions The PED can be utilized for ruptured aneurysms and is a good option for blister-type aneurysms. However, due to periprocedural complications, it should be reserved for lesions that are difficult to treat by conventional clipping or coiling.Keywords
This publication has 21 references indexed in Scilit:
- Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular AneurysmsStroke, 2013
- Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical TrialRadiology, 2013
- Pipeline Embolization Device in Aneurysmal Subarachnoid HemorrhageAmerican Journal of Neuroradiology, 2012
- Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2011
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- The Role of the Pipeline Embolization Device for the Treatment of Dissecting Intracranial AneurysmsAmerican Journal of Neuroradiology, 2011
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysmsJournal of NeuroInterventional Surgery, 2009
- CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- DEFINITIVE RECONSTRUCTION OF CIRCUMFERENTIAL, FUSIFORM INTRACRANIAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2008