Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer
- 26 October 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (22) , N505-N512
- https://doi.org/10.1088/0031-9155/52/22/n01
Abstract
Advanced radiotherapeutical techniques like intensity-modulated radiation therapy (IMRT) are based on an accurate knowledge of the location of the radiation target. An accurate dose delivery, therefore, requires a method to account for the inter- and intrafractional target motion and the target deformation occurring during the course of treatment. A method to compensate in real time for changes in the position and shape of the target is the use of a dynamic multileaf collimator (MLC) technique which can be devised to automatically arrange the treatment field according to real-time image information. So far, various approaches proposed for leaf sequencers have had to rely on a priori known target motion data and have aimed to optimize the overall treatment time. Since for a real-time dose delivery the target motion is not known a priori, the velocity range of the leading leaves is restricted by a safety margin to c x v(max) while the following leaves can travel with an additional maximum speed to compensate for the respective target movements. Another aspect to be considered is the tongue and groove effect. A uniform radiation field can only be achieved if the leaf movements are synchronized. The method presented in this note is the first to combine a synchronizing sequencer and real-time tracking with a dynamic MLC. The newly developed algorithm is capable of online optimizing the leaf velocities by minimizing the overall treatment time while at the same time it synchronizes the leaf trajectories in order to avoid the tongue and groove effect. The simultaneous synchronization is performed with the help of an online-calculated mid-time leaf trajectory which is common for all leaf pairs and which takes into account the real-time target motion and deformation information.Keywords
This publication has 19 references indexed in Scilit:
- IMRT delivery to a moving target by dynamic MLC tracking: delivery for targets moving in two dimensions in the beam's eye viewPhysics in Medicine & Biology, 2006
- Abdominal organ motion measured using 4D CTInternational Journal of Radiation Oncology*Biology*Physics, 2006
- Simulation and visualization of dose uncertainties due to interfractional organ motionPhysics in Medicine & Biology, 2006
- An improved MLC segmentation algorithm and software for step‐and‐shoot IMRT delivery without tongue‐and‐groove errorMedical Physics, 2006
- Real‐time DMLC IMRT delivery for mobile and deforming targetsMedical Physics, 2005
- Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targetsMedical Physics, 2005
- DMLC leaf‐pair optimal control for mobile, deforming targetMedical Physics, 2005
- Optimal leaf sequencing with elimination of tongue-and-groove underdosagePhysics in Medicine & Biology, 2004
- Effects of motion on the total dose distributionSeminars in Radiation Oncology, 2004
- Segmental and dynamic intensity-modulated radiotherapy delivery techniques for micro-multileaf collimatorMedical Physics, 2003