Optimal leaf sequencing with elimination of tongue-and-groove underdosage
- 16 January 2004
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (3) , N7-N19
- https://doi.org/10.1088/0031-9155/49/3/n01
Abstract
The individual leaves of a multileaf collimator (MLC) have a tongue-and-groove or stepped-edge design to minimize leakage radiation between adjacent leaves. This design element has a drawback in that it creates areas of underdosages in intensity-modulated photon beams unless a leaf trajectory is specifically designed such that for any two adjacent leaf pairs, the direct exposure under the tongue-and-groove is equal to the lower of the direct exposures of the leaf pairs. In this work, we present a systematic study of the optimization of a leaf sequencing algorithm for segmental multileaf collimator beam delivery that completely eliminates areas of underdosages due to tongue-and-groove or stepped-edge design of the MLC. Simultaneous elimination of tongue-and-groove effect and leaf interdigitation is also studied. This is an extension of our previous work (Kamath et al 2003a Phys. Med. Biol. 48 307) in which we described a leaf sequencing algorithm that is optimal for monitor unit (MU) efficiency under most common leaf movement constraints that include minimum leaf separation. Compared to our previously published algorithm (without constraints), the new algorithms increase the number of sub-fields by approximately 21% and 25%, respectively, but are optimal in MU efficiency for unidirectional schedules.Keywords
This publication has 14 references indexed in Scilit:
- Leaf sequencing algorithms for segmented multileaf collimationPhysics in Medicine & Biology, 2003
- The MLC tongue-and-groove effect on IMRT dose distributionsPhysics in Medicine & Biology, 2001
- An experimental investigation of the tongue and groove effect for the Philips multileaf collimatorPhysics in Medicine & Biology, 1998
- Generation of discrete beam-intensity modulation by dynamic multileaf collimation under minimum leaf separation constraintsPhysics in Medicine & Biology, 1998
- Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profilesPhysics in Medicine & Biology, 1998
- Dynamic multileaf collimation without `tongue-and-groove' underdosage effectsPhysics in Medicine & Biology, 1996
- Field shaping for three-dimensional conformal radiation therapy and multileaf collimationSeminars in Radiation Oncology, 1995
- Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimationsMedical Physics, 1994
- Combining multileaf fields to modulate fluence distributionsInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Characterization of a multileaf collimator systemInternational Journal of Radiation Oncology*Biology*Physics, 1993