Transmit and receive transmission line arrays for 7 Tesla parallel imaging
Top Cited Papers
Open Access
- 27 January 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (2) , 434-445
- https://doi.org/10.1002/mrm.20321
Abstract
Transceive array coils, capable of RF transmission and independent signal reception, were developed for parallel, 1H imaging applications in the human head at 7 T (300 MHz). The coils combine the advantages of high‐frequency properties of transmission lines with classic MR coil design. Because of the short wavelength at the 1H frequency at 300 MHz, these coils were straightforward to build and decouple. The sensitivity profiles of individual coils were highly asymmetric, as expected at this high frequency; however, the summed images from all coils were relatively uniform over the whole brain. Data were obtained with four‐ and eight‐channel transceive arrays built using a loop configuration and compared to arrays built from straight stripline transmission lines. With both the four‐ and the eight‐channel arrays, parallel imaging with sensitivity encoding with high reduction numbers was feasible at 7 T in the human head. A one‐dimensional reduction factor of 4 was robustly achieved with an average g value of 1.25 with the eight‐channel transmit/receive coils. Magn Reson Med 53:434–445, 2005.Keywords
This publication has 28 references indexed in Scilit:
- Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scalingMagnetic Resonance in Medicine, 2004
- Efficient high‐frequency body coil for high‐field MRIMagnetic Resonance in Medicine, 2004
- Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imagingMagnetic Resonance in Medicine, 2002
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Perfusion‐based high‐resolution functional imaging in the human brain at 7 TeslaMagnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Radiofrequency shielding of surface coils at 4.0 tJournal of Magnetic Resonance Imaging, 1995
- High frequency volume coils for clinical NMR imaging and spectroscopyMagnetic Resonance in Medicine, 1994
- Electromagnetic fields of surface coil in vivo NMR at high frequenciesMagnetic Resonance in Medicine, 1991
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986