On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations
Top Cited Papers
- 8 February 2007
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (5) , 1363-1385
- https://doi.org/10.1088/0031-9155/52/5/011
Abstract
A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho correction; Nucletron Helax-TMS: the collapsed cone and the pencil beam with equivalent path length correction; CMS XiO: the multigrid superposition and the fast Fourier transform convolution; Philips Pinnacle: the collapsed cone. Monte Carlo simulations ( MC) performed with the EGSnrc codes BEAMnrc and DOSxyznrc from NRCC in Ottawa were used as a benchmark. The study was carried out in simple geometrical water phantoms(rho = 1.00 g cm(-3)) with inserts of different densities simulating light lung tissue (rho = 0.035 g cm(-3)), normal lung (rho = 0.20 g cm(-3)) and cortical bone tissue (rho = 1.80 g cm(-3)). Experiments were performed for low- and high-energy photon beams (6 and 15 MV) and for square (13 x 13 cm(2)) and elongated rectangular (2.8 x 13 cm(2)) fields. Analysis was carried out on the basis of depth dose curves and transverse profiles at several depths. Assuming the MC data as reference,. index analysis was carried out distinguishing between regions inside the non-water inserts or inside the uniformwater. For this study, a distance to agreement was set to 3 mm while the dose difference varied from 2% to 10%. In general all algorithms based on pencil-beam convolutions showed a systematic deficiency in managing the presence of heterogeneous media. In contrast, complicated patterns were observed for the advanced algorithmswith significant discrepancies observed between algorithms in the lighter materials (rho = 0.035 g cm(-3)), enhanced for the most energetic beam. For denser, and more clinical, densities a better agreement among the sophisticated algorithms with respect to MC was observed.Keywords
This publication has 36 references indexed in Scilit:
- Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to waterPhysics in Medicine & Biology, 2006
- Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systemsPhysics in Medicine & Biology, 2005
- Large efficiency improvements in BEAMnrc using directional bremsstrahlung splittingMedical Physics, 2004
- Commissioning and quality assurance of the Pinnacle3radiotherapy treatment planning system for external beam photonsThe British Journal of Radiology, 2003
- A virtual linear accelerator for verification of treatment planning systemsPhysics in Medicine & Biology, 2000
- Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam dataPhysics in Medicine & Biology, 1996
- Investigation of the convolution method for polyenergetic spectraMedical Physics, 1993
- Acquisition of the effective lateral energy fluence distribution for photon beam dose calculations by convolution modelsPhysics in Medicine & Biology, 1991
- Generation of photon energy deposition kernels using the EGS Monte Carlo codePhysics in Medicine & Biology, 1988
- Verification by Monte Carlo methods of a power law tissue-air ratio algorithm for inhomogeneity corrections in photon beam dose calculationsPhysics in Medicine & Biology, 1980