3He-MRI in follow-up of lung transplant recipients
- 16 October 2003
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 14 (1) , 78-85
- https://doi.org/10.1007/s00330-003-2092-4
Abstract
The aim of this study was to evaluate the possible contribution of 3He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up 3He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume. Bronchiolitis obliterans syndrome (BOS) was diagnosed using pulmonary function tests. At 3He-MRI, OB was suspected if ventilated lung volume had decreased by 10% or more at the follow-up MRI study compared with the initial study. General accordance between pulmonary function testing and 3He-MRI was good, although subjective evaluation of 3He-MRI underestimated improvement in ventilation as obtained by pulmonary function tests. The 3He-MRI indicated OB in 6 cases. According to pulmonary function tests, BOS was diagnosed in 5 cases. All diagnoses of BOS were also detected by 3He-MRI. In 2 of these 5 cases, 3He-MRI indicated OB earlier than pulmonary function tests. The results support the hypothesis that 3He-MRI may be sensitive for early detection of OB and emphasize the need for larger prospective follow-up studies.Keywords
This publication has 28 references indexed in Scilit:
- Bronchiolitis obliterans and lung transplantation: Evidence for an infectious etiologySeminars in Respiratory Infections, 2002
- Quantitative measurement of regional lung ventilation using 3He MRIMagnetic Resonance in Medicine, 2002
- Prospektive Machbarkeitsstudie zum Vergleich von Röntgenübersichtsaufnahme und Thorax-MRT in Atemanhaltetechnik am offenen NiederfeldgerätRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Dynamic Ventilation 3He-Magnetic Resonance Imaging With Lung Motion CorrectionInvestigative Radiology, 2002
- MRI in lung transplant recipients using hyperpolarized3He: Comparison with CTJournal of Magnetic Resonance Imaging, 2002
- Akute oder chronische Transplantat-Abstoßung? - HRCT des Thorax bei Patienten nach LungentransplantationRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001
- Mechanical Delivery of Aerosolized Gadolinium-DTPA for Pulmonary Ventilation Assessment in MR ImagingInvestigative Radiology, 2001
- MRT des LungenparenchymsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001
- Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findingsJournal of Magnetic Resonance Imaging, 2001
- Volumetry of Ventilated Airspaces by 3He MRIInvestigative Radiology, 2001